Laserfiche WebLink
i � <br /> DF-52416:D•A3-2Q <br /> MS-SUD�E)/MS-18tJD{Ej Series � F��.��Te�ALc''�rfl'"1S <br />, F�ve Zone F�re Alarm Gontro[ Panel <br />� Ten Zone Fire Aiarm Control Panei by Honeyweil <br />� <br /> General <br />' The MS-SUD-3(E) is a five-zone FACP (Fire Alarm Control <br /> Panel)and the MS-10UD-7(E)is a ten-zone FACP.These con- <br /> tral panels provide reliabie fire signating protectian for small ta <br /> . medium-sized commercial, industrial, and institutiona� build- <br /> ings. Both panels include built-in communicators for Central <br /> Station Service and remote uploadldawnload. - <br /> Each of these FACPs is compatible with System Sensor's <br /> � microprooessor-based i3 series detectors.These conventional <br /> smoke detectors can transmit a maintenance trauble signal to <br /> ' the FACP indicating the need for cleaning and a supervisory �'"' <br /> "freeze" signal when the ambient temperature falls below the � <br /> detector rating. Additionally, both the MS-5UD-3 and MS- <br />�I , 10UD-7 are compatible with conventional input devices such <br /> E as two-and four-wire smoke detectors,pull stations,waterflow <br /> devices, tamper switches, and other normally-open contact � <br /> devices. Refer to the Fire•Lite Device Compatibility Document <br /> for a complete listing of compatible devices. � Q <br /> Outputs include faur NACs (Notification Appliance Circuits}, " <br /> three programmable Form-C relays (factory programmed for <br /> Alarm,Trouble,and Supervisory)and 24 VDC speeial applica- <br /> tian resettable and nonresettable power outputs. The FACPs <br />� supervise all wiring, AC voltage, battery level and telephone _Strobe 8ynchronization for System Sensor, Wheefock, <br />, line integrity. Gentex,Faraday,or Amseco devices. <br />' Activation af a campatible smoke detector or any normally- _Selective Silence(horn-strobe mute). <br /> open fire alarm initiating device will activate audible and visual <br />' sig�aling devices, iliuminate an indicating LED, saund the —Temparal or S#eady Signal. <br /> , piezo sounder at the FACP, activate the communicator and —5ilenceable or Nansilenceable. <br /> FACP alarm relay, and operate an optianal module used to . Optiona! CAG-5X Style Z (Class A) Converter Module foe <br /> notify a remote statian or initiate an auxitiary control function. NACs and IDCs{2 required for MS-10UD-7}. <br /> New options include a UL listed printer, PRN-6F and FireLite's • Form-C Relays for Alarm, Trouble and Supervisory- Con- <br /> , IPDACT Internet Monitoring module. The FireWatch Series tact Ratings 2.d AC�3d VDC ar 4.5 A t�30 VAG(resistive}. <br /> internet manitoring moduies IPDACT-2 and IPDACT-2UD per- . 3.0 A total system current for MS-5UD-3. <br /> mit monitoring of alarm signals over the Internet saving the 7,0 A total system current far MS-10UD-7. <br /> ' monthly cost of two telephone lines.Atthough not required,the � <br /> secondary telephone tine may be retained providing backup • �P��flnat Dress Panel DA-51050 <br /> communication over the public switched telephone line. • Optional Trim Ring TR-CE for semi-flush mounting. <br /> NG77E.The MS-5Ut?-3E and MS-f0UD-7E offers the same fea- • 24 volt aperation. <br /> tures as the MS-StJD-3 and MS-10UD-7 but aiiow connectian to . Low AC voltage sense. <br /> 240 UAC. Unless othenvise specified,the information in this data Afarm Verification. <br /> sheef appties ta trofh fhe 12P VAC and the 240 UAC versions of � <br /> these panels. • PAS(Positive Alarm Sequence}. <br /> NOTE:For ULC-listed models,see DF-60440. • Automatic battery trickle charger. <br /> • Up to eight ANN-BUS annunciators: <br /> F�Eatur@S —Optional 8 zone Relay Madule ANN-RLY. <br /> • �isted to UL Standard 864,9th edition. —Optionat�ED Annunciator fvtodule ANN-�.ED, I� <br /> • Built-in DACT(Digita�Alarm CommunicatorlTransmitter). —Optional Remote Annunciator ANN-80. <br /> • 8tyle B(Class B)IDC(Initiating Device Cirouit) —Optional Remote Printer Gateway ANN-S/PG. <br /> —MS-5UD-3-tive IdCs. —Optiana(�ED Annunciatar Driver ANN-I10. <br /> —MS-10UD-7-ten IDCs. • Optianal 4XTMF module (conventional reverse palarity/city <br /> • Styte Y{Class B}NAG(Notifica#ian Appliance Circuit)-spe- box transmitter). <br /> cial application power PROGRAMMING AND SOFfWARE: <br /> —MS-5UD-3-four NACs. • Gan be programmed at the panel with no special software <br /> —MS-i OUD-7-four NACs. or additional equipment. <br /> • Notification Appliances may be programmed as • Programmable Make/Break Ratio. <br /> —Sitence Inhibit. • UploadlDownload(local or remo#e)af pragram and data via <br /> —Auto-Silence. integral DACT. <br /> DF-52416:D•07/26/2010—page 1 of 4 <br />