• Minimum Battery Size:7 AH. MS-10UD-7E:Same as above with 240 VAC FLPS-7. <br /> Initiating Device Circuits—T84 (and TB 6 on MS-10UD-7 IpDACT, IPDACT2/2UD Internet Monitoring Module: <br /> only): Mounts in bottom of enclosure with optional mounting kit(PN <br /> • Alarm Zones 1 -5 on TB 4(MS-5UD-3 and MS-10UD-7). IPBRKT). Connects to primary and secondary DACT tele- <br /> • Alarm Zones 6-10 on TB6(MS-10UD-7 only). phone output ports for internet communications over customer <br /> provided ethernet internet connection. Requires compatible <br /> • Supervised and power-limited circuitry. Teldat Visoralarm Central Station Receiver.Can use DHCP or <br /> • Operation:All zones Style B(Class B). static IP. (See data sheet DF-60407 for more information.) <br /> • Normal Operating Voltage:Nominal 20 VDC. IPBRKT: Mounting kit for IPDACT in common enclosure. <br /> • Alarm Current: 15 mA minimum. IPSPLT: Y Adaptor option to allow connection of both panel <br /> • Short Circuit Current:40 mA max. dialer outputs to one cable input to IPDACT(sold separately). <br /> , • Maximum Loop Resistance:100 ohms. OPT/ONAL MODULES <br /> • End-of-Line Resistor: 4.7K ohm, 1/2 watt (P/N 71252 UL- CAC-5X:O tional Class A Converter Module.Converts Style <br /> listed). P� � ) <br /> B(Class B)Initiating Device Circuits to Style D(Class A);and <br /> _ • Standby Current:2 mA. Style Y (Class B) Notification Appliance Circuits to Style Z <br /> Refer to the Fire•Lite Device Compatibiliry Document for listed (Class A). Connects to J2 on the MS-5UD-3 and MS-10UD- <br /> compatible devices. 7(E)main circuit board and to J7 on the MS-10UD-7(E). <br /> Notification Appliance Circuits — TB5 (and TB 7 on MS- NOTE Two C/ass A Converter Modules are required for the ten- <br /> 10UD-7 only): zone panel. <br /> , • Four NACs 4XTMF:Transmitter module. Provides a supervised output for <br /> • Operation:Style Y(Class B) local energy municipal box transmitter and alarm and trouble <br /> Special Application power reverse polarity. Includes a disable switch and disable trouble <br /> � LED.A module jumper option allows the reverse polarity circuit <br /> • Supervised and power-limited circuitry to open with a system trouble condition if no alarm conditions <br /> • Normal Operating Voltage:Nominal 24 VDC exists.Mounts to the main circuit board connectors J4 and J5. <br /> • Maximum Signaling Current: 3.0 A for MS-5UD-3, 2.5 A COMPATIBLEANNUNC/ATORS <br /> maximum per NAC; 7.0 A for MS-10UD-7(E), 3.0 A maxi- <br /> mum per NAC. ANN-80: Remote LCD Annunciator. Mimics the information <br /> • End-of-Line Resistor:4.7K ohm,1/2 watt(Part#71252) displayed on the FACP's LCD. Red. (For white, order: ANN- <br /> 80-W.) <br /> • Max.Wiring Voltage Drop:2 VDC ANN-LED: LED Annunciator with three LEDs for each zone: <br /> Refer to the Fire•Lite Device Compatibility Document for com- Alarm, Trouble, and Supervisory. Mounts in the DP-51050(B) <br /> patible listed devices. dress panel.Red.(For white,order ANN-LED-W.) <br /> Form C Relays—TB8: ANN-RLED: LED Annunciator with three alarm (red) indica- <br />� Re/a i fac <br /> y ( tory defauit programmed as Alarm Relay) tors for up to 30 input zones or addressable points.(Red. For <br /> • Relay 2 (factory default programmed as fail-safe Trouble White,orderANN-LED-W.)(See DF-60241). <br /> Relay) ANN-RLY: Relay module.Mounts inside the cabinet. Provides <br /> • Relay 3(factory default programmed as Supervisory Relay) ten Form C relays. <br /> Special Application Resettable Power—T89: ANN-S/PG:SeriaVparallel printer gateway.Provides a connec- <br /> • Jumper selectable by JP31 for resettable or nonresettable tion for a serial or parallel printer. <br /> power. ANN-U0: Driver module. Provides connections to a user-sup- <br />, • Operating voltage:24 VDC nominal. plied graphic annunciator. <br /> • Maximum available current:500 mA-appropriate for pow- ACCESSORIES <br /> ering four-wire smoke detectors. DP-51050: Optional dress panel. Restricts access to the sys- <br /> • Power-limited circuit. tem wiring while allowing access to the membrane switch <br /> Refer to the Fire•Lite Device Compatibility Document for listed panel. <br /> compatible devices. BB-26: Battery backbox, holds up to two 25 AH batteries and <br /> Remote Sync Output-TB2: Remote power supply synchro- CHG-75. <br /> nization output,only required for the MS-5UD-3.24 VDC nom- BB-55:Battery backbox,holds up to two 25 AH batteries. <br /> inal special application power. Maximum current is 40 mA. <br /> End-of-Line Resistor: 4.7K ohm. Supervised and power-lim- TR-CE:Optional trim-ring for semi-flush mounted cabinets. <br /> ited circuit. PRN-6F:UL listed printer. <br /> Product Line Information <br /> MS-5UD-3: Five-zone, 24-voit Fire Alarm Control Panel <br /> (includes backbox, FLPS-3 power supply, technical manual, <br /> and a frame & post operating instruction sheet). 120 VAC <br /> operation. <br /> MS-5UD-3E: Same as MS-5UD-3 except for 240 VAC opera- <br /> tion. I <br /> MS-10UD-7: Ten-zone, 24-volt Fire Alarm Control Panel <br /> (includes backbox, FLPS-7 power supply, technicai manuai, I <br /> and a frame&post operating instruction sheet). <br /> DF-52416:D•07/26/2010—Page 3 of 4 <br />