df-52417:c•B-90 <br /> AN N-8o � Fire•��Te�A�arms <br /> 80 Character LCD <br /> serial �►nnunciator by Honeywell <br /> General <br /> The ANN-80 annunciator is a compact, backlit, SO-character <br /> LCD fire annunciator that mimics the Fire Alarm Control Panel <br /> (FACP) display. It provides system status indicators for AC <br /> . Power,Alarm,Trouble, Supervisory, and Alarm Silenced condi- <br /> tions.The ANN-SO and the FACP communicate over a two-wire <br /> serial intertace employing the ANN-BUS communication format. <br /> Connected devices are powered, via two additional wires, by <br /> • either the host FACP or a remote UL-listed,filtered power supply. <br /> ANN-80 is red;for white,order ANN-80-W. r�i <br /> • The ANN-80 displays English-language text of system point <br /> information including device type, zone, independent point <br /> alarm, trouble or supervisory status, as well as any custom <br /> alpha labels programmed into the control panel.It includes con- � : <br /> ' trol switches for remote control of critical system functions. (A <br /> keyswitch prevents unauthorized operation of the control <br /> switches.) <br /> Up to eight ANN-SOs may be connected to the ANN-BUS of _ - - <br /> each FACP. No programming is required,which saves time dur- <br /> ing system commissioning. <br /> Features <br /> • Listed to UL Standard 864,9th Edition. <br /> • Backlit 80-character LCD display(20 characters x 4 lines). • Supervisory <br /> • Mimics all display information from the host panel. • Alarm Silenced <br /> • Control switches for System Acknowledge, Signal Silence, <br /> Drill,and Reset. Specifications <br /> • Control switches can be independently enabled or disabled • Operating voltage range:18 VDC to 28 VDC. <br /> at the FACP. • Current consumption @ 24 VDC nominal(filtered and non- <br /> • Keyswitch enablesldisables control switches and mechani- resettable):40 mA maximum. <br /> cally locks annunciator enclosure • Ambient temperature:32°F to 120°F(0°C to 49°C). <br /> • Keyswitch can be enabled or disabled at the FACP. • Relative humidity:93%t 2%RH (noncondensing)at 32°C <br /> • Enclosure supervised for tamper. t 2°C(90°F t 3°F). <br /> • System status LEDs for AC Power, Alarm, Trouble, Supervi- • 5.375" (13.65 cm.) high x 6.875" (17.46 cm.) wide x 1.375" <br /> sory,and Alarm Silence. (3.49 cm.)deep. <br /> • Local sounder can be enabled or disabled at the FACP. • For use indoors in a dry location. <br /> • ANN-80 connects to the ANN-BUS terminal on the FACP and • All connections are power-limited and supervised. <br /> requires minimal panel programming. <br /> • Displays device type identifiers, individual point alarm, trou- pgency Listings and Approvals <br /> ble,supervisory,zone,and custom alpha labels. <br /> • Time-and date display field. The listings and approvals below apply to the ANN-S0. In some <br /> cases, certain modules may not be listed by certain approval <br /> • Surface mount directly to wall or to single, double, or 4" agencies,or listing may be in process.Consult factory for latest <br /> square electrical box. listing status. <br /> • Semi-flush mount to single, double, or 4" square electrical . UL:S2424 <br /> box.Use ANN-SB80KIT for angled view mounting. <br /> Can be remotely located up to 6,000 feet(1,800 m)from the ' FM approved <br /> • panel. • CSFM:7120-0075211 <br /> • Backlight turns off during AC loss to conserve battery power • MEA:442-06-E <br /> ' but will turn back on if an alarm condition occurs. <br /> • May be powered by 24 VDC from the host FACP or by remote The ANN-BUS <br /> power supply(requires 24 VDC). <br /> • Up to eight ANN-80s can be connected on the ANN-BUS. POWERING THE DEVICES ON THE ANN-BUS FROM <br /> AUXIL/ARY POWER SUPPLY <br /> Controls and Indicators The ANN-BUS can be powered by an auxiliary power supply <br /> • AC Power when the maximum number of ANN-BUS devices exceeds the <br /> ANN-BUS power requirements.See the FACP manual for more <br /> • Alarm information. <br /> • Trouble <br /> df-52417:c•05/22/09—Page 1 of 2 <br />