Laserfiche WebLink
Specifications Agency Listings and Approvals <br /> PHYSICAL SPECIF/CATIONS: The listings and approvals below apply to the BG-12 Series pull <br /> stations. In some cases,certain modules may not be listed by <br /> certain approval agencies,or listing may be in process.Consult <br /> pull station SB-u0 SB-10 factory for latest listing status. <br /> Height 5.5 inches 5.601 inches 5.5 inches • C(UL)US:S711 <br /> (13.97 cm) (14.23 cm) (13.97 cm) • FM Approved <br /> Width 4.121 inches 4.222 inches 4.121 inches • CSFM:7150-0075:184 <br /> (10.47 cm) (10.72 cm) (10.47 cm) <br /> • MEA:67-02-E <br /> Depth �•39 inches 1 439 inches 1.375 inches . Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; <br /> (3.53 cm) (3.66 cm) (3.49 cm) 6,632,108. <br /> 52004dim.f61 <br /> ELECTRICAL SPECIFICATIONS: Product Line Information <br /> Switch contact ratings:gold-plated;rating 0.25 A@ 30 VAC or BG-12S: Single-action pull station with pigtail connections,hex <br /> VDC. <br /> . lock. <br /> ENGINEERING/ARCHITECTURAL SPEClF/CATIONS BG-12SL: Same as BG-12 with key lock. <br /> - Manual Fire Alarm Stations shall be non-code, with a key- or BG-12: Dual-action pull station with SPST N/O switch, screw <br /> hex-operated reset lock in order that they may be tested,and so terminal connections,hex/ock. <br /> designed that after actual Emergency Operation,they cannot be BG-12L: Same as BG-12 with key lock. <br /> restored to normal except by use of a key or hex. An operated BG-12LSP: Same as BG-12L with English/Spanish (FIRE/ <br /> ' station shall automatically condition itself so as to be visually FUEGO)labeling. <br /> detected as activated. Manual stations shall be constructed of gG-12LOB: Same as BG-12L with "outdoor use" listing. <br /> red colored LEXAN (or polycarbonate equivalent) with clearly Includes outdoor listed backbox,and sealing gasket. <br /> visible operating instructions provided on the cover. The word <br /> FIRE shall appear on the front of the stations in white letters, BG-12L0: Same as BG-12L with "outdoor use° listing. Does <br /> 1.00 inches (2.54 cm) or larger. Stations shall be suitable for not include backbox. <br /> surface mounting on matching backbox SB-10 or SB-I/O; or BG-12LA: Same as BG-12L with auxiliary contacts. <br /> semi-flush mounting on a standard single-gang,double-gang,or gG-12LPS: Dual-action pull station with pre-signal option. <br /> 4"(10.16 cm)square electrical box,and shall be installed within BG-12LPSP: Same as BG-12LPS with English/Spanish (FIRE/ <br /> the limits defined by the Americans with Disabilities Act(ADA)or FUEGO)labeling. <br /> per national/local requirements.Manual Stations shall be Under- <br /> writers Laboratories listed. SB-10: Surface-mount backbox,metal. <br /> NOTE:'The words F/RE/FUEGO"on the BG-12LSP shall appear SB-UO: Surface-mount backbox, plastic. (Included with BG- <br /> on the front of the station in white letters, approximately 3/4" 12L08.) <br /> (1.905 cm)high. BG72TR: Optional trim ring for semi-flush mounting. <br /> •�- -- - - - --.� 17003:Keys,set of two.(Included with key-lock pull stations.) <br /> i <br /> 17007:Hex lock,9/64".(Included with hex-lock pull stations.) <br /> i NOTE: For addressable BG-12LX models, see data sheet DF- <br /> � 52013. <br /> i <br /> � <br /> i <br /> i ° � � � <br /> � � � <br /> . <br /> � ,• ; <br /> i ' <br /> � <br /> � � <br /> I �.--�.��. . � ,, � ; <br /> �'�����.`'��'�,� { <br /> _ . i <br /> Fire•Lite� Alarms, SpectrAlert� Advance, and System Sensor(� are <br /> registered trademarks of Honeywell Intemational Inc. <br /> 002008 by Honeywell Intemational Inc.All rights reserved.Unauthorized use <br /> of this document is strictly prohibited. <br /> 1S0 �oo� This document is not intended to be used tor installation purposes. <br /> We try to keep our product information up-to-date and accurate. <br /> - We cannot cover all specific applications or anticipate all requirements. <br /> 6Y61NE�IN�6 MlWOFACTIINIV6 Ali specifications are subject to change without notice. <br /> QUALITY SYSTEMS MadeintheU.S.A. I <br /> For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX.(877)699-4105. ' <br /> www.firelite.com <br /> Page 2 of 2—DF-52004:A1•04/2?J08 <br />