My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
16-17418
Zephyrhills
>
Building Department
>
Permits
>
2016
>
16-17418
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/1/2016 11:43:28 AM
Creation date
11/1/2016 11:42:16 AM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYR II LLC
Building Department - Doc Type
Permit
Permit #
16-17418
Building Department - Name
ZEPHYR II LLC
Address
5935 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
13. SYSTEM POWER(continued) <br /> 13.1.3 Uninterruptible Power System L'1"lhis system does not have a UPS. <br /> Equipment powered by a UPS system: <br /> Location of UPS system: <br /> Calculated capacity of UPS batteries to drive the system components connected to it: <br /> In standby mode(hours): In alarm mode(minutes): <br /> , 13.1.4 Batteries <br /> Location: _ _ri{��C� ___ _ Type: PiG� _ Nominal voltage: (_`Z-___ Amp/hour rating: `7 Afli�' <br /> , Calculated capacity of batteries to drive the system: <br /> i <br /> In standby mode(hours): 'Z Y In alarm mode(minutes): 5 <br /> . ❑Batteries are marked with date of manufacture ❑Battery calculations are attached <br /> 13.�-Building Fire Emergency Voice Alarm Communication System or Mass Notification System <br /> This system does not have an EVACS or MNS system. <br /> 13.2.1 Primary Power <br /> Input voltage of EVACS or MNS panel. _ _ _ EVACS or MNS panel amps: _ __ <br /> Overcunent protection: Type: Amps: <br /> Location(of primary supply panel board): <br /> Disconnecting means location: <br /> 13.2.2 Engine-Driven Generator �'lhis system does not have a generator. <br /> Location of generator: <br /> Location of fuel storage: Type of fuel: <br /> ..� .___�._.. - - �- ----- - ------- - - - --- --.. ._.._ .. ._..---- ----- __ _- - <br /> 13.2.3 Uninterruptible Power System [�This system does not have a UPS. <br /> Equipment powered by a UPS system: <br /> Location of UPS system: <br /> Calculated capacity of UPS batteries to drive the system components connected to it: <br /> In standby mode(hours): In alarm mode(minutes): <br /> 13.2.4 Batteries <br /> Location: Type: _ Nominal voltage: __ __ _ _ ___ Amp/hour rating: __A___ __ <br /> Calculated capacity of batteries to drive the system: <br /> In standby mode(hours): In alarm mode(minutes): <br /> � ❑Batteries are marked with date of manufacture ❑Battery calculations are attached <br /> NFPA 72, Fig. 10.182 1.1 (p.9 of 12) <br /> Copyright OO 2009 NaGonal Fire Protection Association.This fortn may be copied for individual use other than for resale.It may not be copied for commercial sale or distribution. <br />
The URL can be used to link to this page
Your browser does not support the video tag.