Laserfiche WebLink
e <br /> ,,' <br /> rr <br /> )�`.. <br /> f <br /> �� r' ��I���� E�Q <br /> TABLE lA: WOOD DECKS-NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVER <br /> SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER <br /> System Deck Top Insulation Layer MDP <br /> Base Insulation Layer Roof Cover/Adhesive <br /> No. (See Note 1) Type Fasteners Attach (psf) <br /> � Min.1.5-inch Poly ISO 1,H- <br /> W-1 Min.19/32"plywood or wood plank (Optional)One or more layers,any Shield,ACFoam II,Poly ISO 2 or See Note 2 1 per 2 ft� Mule-Hide TPO-c/WBBA 2000 or _q5.0" <br /> combination,loose laid ENRGY 3 Mule-Hide TPO-c Bonding Adhesive <br /> TABLE 1B: WOOD DECKS—NEW CONSIRUCTION,REROOF(Tear-Off)or RECOVER <br /> SYSTEM TYPE D: INSULATED,MECHANICALLY ATTACHED ROOF COVER <br /> Insulation Layer <br /> System Roof C�ver MDP <br /> No. Roof Deck (See Note 14) <br /> (psf) , <br /> Type Attath Memhrane F�steners �pacing <br /> Min.19/32•inch plywood or wood plank at <br /> W z max.24"spans attached using Sd ring shank One or more layers, Preliminarily Mule�Hide Mule-Hide EHD Fasteners and 2.4 6-in�h o.c.within 5.5-inch wide laps spaced 90.5 inch -52.5 <br /> nails spaced 6"o.c.in the field and q10 ring any combination attached TPO-c Seam Plates o c. Outside of lap sealed with 1.S�inch heat weld <br /> shank nails spaced 4"o c at the perimeter <br /> Min.19/32-inch plywood or wood plank at . <br /> W 3 max.24"spans attachFd using 8d ring shank One or more layers, Preliminarily Mule Hide Mule�Hide EHD Fasteners and 2.4 6-inch o.c.within 5.5-inch wide laps spaced 66 5-inch .67.5 <br /> nails spaced 6"o.c.in the field and k10 ring any combination attached TPO-c Seam Plates o.c. Outside of lap sealed with 1.5-inch heat weld <br /> shank nails spaced 4"o c.at the perimeter <br /> 6-inch o.c.within S�inch wide laps spaced 67 inch o[. <br /> Min.23/32-inch OSB at max.24-inch spans Outside of lap sealed with 1.5-inch heat weld <br /> attached using 8d ring shank nails spaced 6" One or more layers, Preliminarily Mule Hide Mule�Hide EHD Fasteners and 2.4 and <br /> W-4 o c.in the field and 8"o c at intermediate any combination attached 1 PO-c Seam Pl,:tes 6 inch o.c,in one row crnte�ed between the laps. 67 5 <br /> supports , Center row covered with 6 inch wide cover strip <br /> sealed with 15-inch heat weld at all edgPs <br /> .� <br /> Exterior ResParch and Design,LLC.d/b/a Trinity�ERD Fvaluation Report M15060 C6 09 R3 for I 112772 R3 <br /> Certifirate o(Authorization 7J9503 ' Rrvision 3:03/]3/7015 <br /> Prepared by� Robert Nieminen,PE 59:t�6 Appendiz 1,Page 3 of 78 <br /> � <br />