<br /> TABLE 2A: STEEL or CONCRETE DECKS-NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVER
<br /> SYSTEM TYPE B: MECHANICAILY AT7ACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER
<br /> System Deck Base Insulation Layer Top Insulation Layer MDP
<br /> No. (See Note 1) Type Fastener Attach Type Attach Koof Cover/Adhesive (Psf)
<br /> Min,22 ga.,type B, Min.0.5-inch Dens Geck or Dens Min.1.5-inch ACFoam II,Poly ISO 2, Mule-Hide TPO-c/WBBA 2000
<br /> SC-1 Grade 33 steel or min. See Note 2 1 per 2.0 ft= ENRGY 3,Poly ISO 1 or H-Shield followed OB500 or Mule-Hide TPO-c Bonding -37.5"
<br /> 2,500 psi concrete Deck Prime by Min.0.25-inch Dens Deck Prime Adhesive
<br /> Min.22 ga.,type B, Min.2-inch Poly ISO] F+Shield,H- z Min 0.25-inch SECUROCK Gypsum-Fiber Mule-Hide TPO-c/WBBA 2000 +
<br /> SC-2 Grade 33 steei or min. Shield CG See Note 2 1 per 4.0 ft Roof Board Ob500 or Mule Hide TPO-c Bonding -37.5
<br /> 2,500 psi conc. Adhesive
<br /> Min.22 ga.,type B, Mule-Hide TPO-c/WBBA 2000
<br /> Min.1.5-inch ACFoam II,Poly ISO Z .
<br /> SC-3 Grade 33 steel or min. 1,Poly ISO 2,H-Shield CG,ENRGY 3 See Note 2 1 per 2.0 ft Additional layers of b�se insulation OB500 or Mule Hide TPO-c Bonding -45.0
<br /> 2,500 psi concrete Adhesive
<br /> Min.22 ga.,type B, Mule ��ide TPO-c/WBBA 20u0
<br /> SC-4 Grade 33 steel or min. Min.1.5-inch ACFoam II,Poly ISO See Note 2 1 per 2.0 ft' Min.0.25-inch Dens Deck,Dens Deck pg500 or Mule-Hide TPO-c Bonding 45.0°
<br /> 1,Poly ISO 2,H-Shield CG,ENRGY 3 Prime
<br /> 2,500 psi concrete Adhesive
<br /> Min.22 ga.,type B, Min.0.5-inch Dens Deck or Dens i Min.1.5-inch ACFoam II,Poly ISO 2, Mule Hide TPO-c/WBBA 2000 {
<br /> SC-5 Gr3de 33 steel or min. Deck Prime See Note 2 1 per 2.0 ft ENRGY 3,H�Shield or Poly ISO 1 OB500 or vlule�Hide TPO-c Bonding -45.0
<br /> 2,500 psi concrete Adhesive
<br /> Min.22 ga.,type B, Mule-Hide TPO-c/WBBA 2000
<br /> Min.2 0-inch ACFoam II,Poly ISO 2 �
<br /> SC-6 Grade 33 steel or min. 1,Poly ISO 2,H-Shield CG,ENRGY 3 See Note 2 1 per 4.0 ft Additional layers of base insulation OB500 or Mule-Hide TPO-c Bonding �45.0
<br /> 2,500 psi concrete Adhesive
<br /> Min.22 ga.,type B, Mule Hide TPO-c/WBBA 2000
<br /> Min.2 0-inch ACFoam II,Poly I50 , Min.0.25-inch Dens Deck,Dens Deck ,
<br /> � SC-7 Grade 33 steel or min. � poly I50 2,H-Shield�G,ENRGY 3 See Note 2 1 per 4.0 ft prime OB500 or Mule�Hide TPO-c Bonding �45.0
<br /> 2,500 psi concrete Adhes�ve
<br /> Min.22 ga.,type B, Min.1.5-inch Poly ISO 7,I�-Shield, j z Min.0.25-inch SECUROCK Gypsum-Fiber Mule Hide TPO-c/WBBA 2000 *
<br /> SC-8 Grade 33 steel or min. H�Shield CG Pe Note 2 1 per 3.2 ft Roof Board OB500 or Mule Hide TPO-c Bunding 45.0
<br /> 2,500 psi conc. Adhesive
<br /> Min.22 ga.,type B, Min.2-inch Poly ISO],H�Shield,H- , Min 0.25-inch SECUROCK Gypsum-Fiber Mule Hide TPO-c/WBBA 2000 y
<br /> SC-9 Grade 33 steel or min. Shield CG See Note 2 1 per 2.67 ft Roof Board OB500 or Mule�Hide TPO-c Bonding �45.0
<br /> 2,500 psi conc. Adhesive
<br /> Min.22 ga.,type B, Min.2 inch Poly ISO 1,H-Shield,H- Z Min 0.25-inch SFCUROCK Gypsum-Fiber Mule Hide TPO-c/WBBA 2000
<br /> SC-10 Grade 33 steel or min. Shield CG See Note 2 1 per 1.6 ft Roof Board OB500 or Mule-Hide TPO-c Bonding -60.0
<br /> 2,500 psi conc. Adhesive
<br /> Exterior Research and Design,LLC.d/b/a Trinity�ERD Evalu,+tion Report M15060.06.09 R3 for FL12772-R3
<br /> Certifi�ate o(Authci itation N9503 Revk�on 3:03/18/2015
<br /> Prepared by� Rcbert Nieminen,PE-59166 Appt�n�ix 1,Page 5 of 18