My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
16-17463
Zephyrhills
>
Building Department
>
Permits
>
2016
>
16-17463
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/1/2016 12:37:00 PM
Creation date
11/1/2016 12:36:57 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
16-17463
Building Department - Name
CAREW,LESLIE & MARSHALL
Address
38744 SOUTH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� Page 3 of 3 <br /> • , <br /> � opaque panels,but is required on glazed panels.See DWG-MA-FL0129- j <br /> O5. I <br /> i <br /> 4904.6 Wood-edge Steel Side-Hinged Door Units 6'-8"Glazed I�S and O/S Door w/or w/o Sidelites <br /> Limits of Use Certificatian�Agency Certificate <br /> Approvcd for use in HVHZ:Yes FLa904 R7_C CAC Nf0061_10,03_pdf <br /> Approved for use outside HVHZ:Yes Quality Assu�•ance Conh•act Expiration Date <br /> Impact R.esistanh No 12/31/2020 �, <br /> Design Pressure;+50.5/-SO.S Installation Insh�uctians <br /> Other:Evaluated for use in locations adliering to tlie Florida Building FL4904 R7 [I FL0130.ndf <br /> Code including the High Velocity Hurricane Zone,and where pressure Verified By•National Accredit�tion&Management Institute <br /> requirements as determined by ASCE 7,Minimum Design Loads for Created by In�dependent Third Party• <br /> I3uildings and Other Stnictures,does not exceed the design pressures �vTluation R'eports <br /> listed. 12'-0"x 6'-8"max nominal size.When large missile impact FL4904 R7 AE 502A_pdf <br /> resistance is required,hurricane protectiva system is required.See DWG- Created by Inldependent Third Party:Yes <br /> MA-FL0130-OS for details. <br /> 4904 7 Wood-edge Steel Side-Hinged Door Units 8'-0"Glazed I S Door w/or w/o Sidelites <br /> Limits of Use Certification rlgency Certificate <br /> Approved for use in HVHZ:Yes FL4904 R7 C CAC NI006110.04..pdf <br /> rlpproved for use outside HVHZ:Yes Quality Assu�ance Contract Gxpir�tion Date <br /> lmpact R.esist�nt:No 12/31/2020 ' <br /> Design I'ressure:+40.0/-45 0 Installation Ihstructions <br /> Other:Evaluated for use in locations adhering to tlie Florida Building FL4904 R7 [I FL013l,�df <br /> Code including the High Velociry Hurricane Zone,and where pressure Verified By:�Jational Accreditation&Management Institute <br /> requirements as determined by ASCE 7,Minimum Design Loads for Created by[n�dependent Third Party: <br /> Buildings and Other Structures,does not exceed the design pressures Evaluation Reports <br /> listed. 12'-0"x 8'-0"max nominal size.When large missile impact FL4904_I2? AE_SOIA,,pdf <br /> resistance is required,liurricane protective system is required.See DWG- Created by Independent Titird Party'Yes <br /> MA-FL0131-OS for details. <br /> 4904.8 Wood-edge Steel Side-Hinged Door Units 8'-0"Glazed O/S Door w/or w/o Sidelites <br /> Limits of Use Certification IAgency Certificate <br /> Approved for use in HVHZ:Yes FL4904 R7 �C CAC N10061 10.04.ndf <br /> r�pproved for use outside HYHZ:Yes Quality Assu�•nnce Conh•act Cxpir�tion Date <br /> Impact R.esistant:No 12/31/2020 � <br /> Design Pressure:+45.0/-40 0 Installation I structions <br /> Other;Evaluated for use in locations adliering to the Florida Building FL4904 R7 1 FL0131.ndf <br /> Code induding the High Velocity Hurricane Zone,and where pressure Verified By:�Iational Accreditation&Management lnstihite <br /> requirements as determined by ASCE 7,Minimtun Design Loads for Created by Ir�dependent Third Party: <br /> Buildings and Other Structures,does not exceed the design pressures Cvaluation Reports <br /> listed. 12'-0"x 8'-0"max nominal size.When large missile impact FL4904 R7 AE SOIA.ndf <br /> resistance is required,liurricane protective system is required.See DWG- Created by Iijdependent Third Party:Yes <br /> MA-FL0131-OS for details. I <br /> I <br /> I <br /> I <br /> � <br /> I <br /> � <br /> I <br /> http://wvvw.floridabuilding.org/pr/pr_app_dtl.aspx?param=w�EVXQwtDqteluIwHNbblSci.., 4/3/2016 <br />
The URL can be used to link to this page
Your browser does not support the video tag.