Laserfiche WebLink
' ,. <br /> � <br /> ����JIT�Y�ER.� � <br /> 11. For existing substrates in a bonded recover installation,the existing roof surfa�e shall be examined for compatibility and bond performance with the selected adhesive,and the existing roof system shall be capable of <br /> resisting project design pressures on its own merit to the satisfaction of the AHJ,as documented through field uplift testing in accordance with ASTM E907,FM LPDS 1-52 or ANSI/SPRI IA-1. <br />, 12. For Recover Applications using System Type D,the insulation is optional. Alternatively,min.0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra, <br />, Structodek High Density Fiberboard Roof Insulation,EnergyGuard RH HD Polyiso Insulation,EnergyGuard HD Polyiso Insulation or EnergyGuard HD Plus Polyiso Insulation or min.0.25-inch Dens Deck,Dens Deck Prime <br /> or SECUROCK Gypsum-Fiber Roof Board or SECUROCK Glass-Mat Roof Board may be used as a separetor board prior to base sheet installation. The existing roof system shall be suitable for a recover application. The <br /> separator component shail be documented as meeting fBC 1505.1 and,for foam plastic,FBC 2603.4.1 or 2603.6,when installed with the roof cover in Recover applications. <br /> 13. Unless otherwise noted,refer to the following references for bonded base,ply or cap sheet applications. <br /> Reference Layer Material Application <br /> gp_qq Base: GAFGLAS tf75 Base Sheet,Tri-Ply#75 Base Sheet,GAFGLAS q80 Ultima Base Sheet <br /> Hot asphalt at 25 Ibs/square. <br /> (Base/Ply sheets,Asphalt-Applied) Ply: One or more plies GAFGLAS Ply 4,Trl-Ply Ply 4,GAFGLAS FlexPly 6 <br /> MatrixT"102 SBS Membrane Adhesive <br /> BP-CA <br /> Base: GAFGLAS t175 Base Sheet,Tri-Ply tt75 Base Sheet (jormerly known as TOPCOAT MATR/X 102 <br /> (Base/Ply sheets,Cold-Applied) SBS Mem6raneAdhesiveJ at 1.5 gal/sq. <br /> B-LL Base: GAFGLAS Stratavent Perforated Venting Base Sheet loose laid <br /> (Base sheet,Loose-Laid) <br /> Base or Ply: One or two plies Ruberoid 20 Smooth,Ruberoid Mop Smooth,Ruberoid Mop Smooth 1.5,Ruberoid Mop Plus Smooth <br /> SBS-AA Ruberoid 30 Granule,Ruberofd 30 Grenule FR,Ruberoid EnergyCap 30 Granule FR,Ruberoid Mop Smooth,Ruberoid Mop Hot asphalt at 25 Ibs/square. <br /> (SBS,Asphalt-Applied) Cap: Smooth 1.5,Ruberoid Mop Plus Smooth,Ruberoid Mop Granule FR,Ruberoid Mop Granule,Tri-Ply SBS Granule,Intec <br /> Flex PRF,Ruberoid Mop Plus Granule FR,Ruberoid Mop Plus Granule,Ruberoid EnergyCap Mop Pius Granule FR <br /> SBS-CA Base or Ply: Ruberoid 20 Smooth Matrix'"102 SBS Membrene Adhesive <br /> (SBS,Cold-Applied,Matrix'"'102 585 Ruberoid 30 Granule FR,Ruberoid EnergyCap 30 Granule FR,Ruberofd Mop Granule FR,Ruberoid Mop Plus Granule FR, (formerly known as TOPCOAT MATRIX 102 <br /> Memhrene Adhesive) �ap' Ruberoid EnergyCap Mop Plus Granule FR SBS MembraneAdhesiveJ at 1.5 gal/sq. <br /> Matrix'"'101 Premium SBS Membrene <br /> SBS-CA-1 Base: Ruberoid 20 Smooth or Ruberoid Mop Smooth 1.5 Adhesive(formerly known as TOPCOAT <br /> (585,Cold-Applied,Matrix`"101 MATRIX Majorbond Modified Bltumen <br /> Premium SBS Membrane Adhesive) �aP: Ruberold 30 Granule FR,Ruberoid EnergyCap 30 Granule FR,Ruberoid Mop Plus Granule FR,Ruberoid EnergyCap Mop MembraneAdhesive)at 1.5-2.0 <br /> Plus Granule FR gal/square <br /> Base or Ply: One or[wo plies Ruberoid HW 25 Smooth,Ruberoid HW Smooth <br /> 585-TA <br /> (SBS,Torch-Applied) Cap; Ruberoid HW Granule,Ruberoid HW Grenule FR,Ruberoid HW Plus Gronule,Ruberoid HW Plus Granule FR,Ruberoid <br /> EnergyCap HW Plus Grenule FR <br /> Torch applied <br /> Base or Ply: One or two plies Ruberoid Torch Smooth,Tri-Ply APP Smooth <br /> APP-TA <br /> (APP,Torch-Applied) Cap: Ruberofd Torch Granule,Tri-Ply APP Granule,Ruberoid Torch Plus Granule FR,Ruberoid EnergyCap Torch Granule FR, <br /> Ruberofd EnergyCap Torch Plus Granule FR <br /> Base or Ply: Liberty SBS Self-Adherfng Base/Ply Sheet <br /> SBS-SA(self-adhering) Self-adhered <br /> Cap Liberty SBS Self-Adhering Cap Sheet <br /> 14. "MDP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads.Refer to FBC 1609 for determination of design wind loads. <br /> Exterior Research and Design,LLC.d/b/a Trinity�ERD Evaluation Report 01506.11.04-R15 for FL5680-R15 <br /> Certificate of Authorization q9503 Revfsion 15:04/06/2015 <br /> Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 3 of 76 <br />