My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
16-17553
Zephyrhills
>
Building Department
>
Permits
>
2016
>
16-17553
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/2/2016 10:43:07 AM
Creation date
11/2/2016 10:43:06 AM
Metadata
Fields
Template:
Building Department
Company Name
GRAND HORIZONS
Building Department - Doc Type
Permit
Permit #
16-17553
Building Department - Name
FLOYD,WILLIAM M & KAREN
Address
37615 COREY LEWIS AVE LOT 326
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> d - -- . <br /> FL 7271.9-R3 � <br /> C 1999-17 <br /> 3.20.15 <br /> Page 2 of 3 <br /> Manufacturer: Unian Corrugating.Company <br /> Product Name: MasterRib Panel <br /> Panel Description: 36"wide coverage with 3/4"high ribs at 9" o.c. <br /> Materials: Minimum 29 ga., 80 ksi steel. Galvanized coated steel (ASTM A653) <br /> or Galvalume coated steel (ASTM A792) or painted steel (ASTM <br /> A755). � <br /> New Underlayment: Minimum underlayment as per FBC 2007 Section 1507.4.5.1. <br /> Required for new construction and optional for reroofing construction. <br /> � Existing Underlayment: One layer of asphalt shingles over one layer of#30 felt.For reroofing , <br /> (Optional) construction only. " I <br /> Deck Description: Min. 15/32" thick APA rated plywood or min. 3/4" thick wood plank � <br /> . (min SG of 0.42) for new and existing constructions. Designed by <br /> _ ' '= '�• -' '�others and installed as.per FBC 2014. <br /> . ,;_ <br /> , t' - �' • i <br /> JSlope:r-:,:i�/���.�` -�-� ''��+�'• "'�'1/2:12 or greater in accordance with FBC 2014 Section 1507.4.2 � <br /> Design Uplift Pressure: 45.0 psf @ fastener spacing of 24" o.c. <br /> (Factor of Safety=2) 113.1 psf @ fastener spacing of 12" o.c. <br /> Panel Attachment: #9-15 or#10-14 x 1.5" long wood screw with washer <br /> At pane��-ends�.,.. >�"��� ''' -��@ 5.5"-3.5"-5.5" o.c. across panel width <br /> � i �,.�� ,:S <br /> ' At intermerliate`.,';�:` �'' `�<;i@ 9"o.c. across panel width ' <br /> !l. 1'� �l}.�;= ,}i`ir�r'`i`i��`• <br /> _ '�idelap�A�tachni�rit: `'�� �'174"-14 x 7/8" long SDS with washer @ m�24" o.c. <br /> , Y �:..�, <br /> Test Standards: Roof assembly tested in accordance with IJL580-94 `Uplift Resistance <br /> of Roof Assemblies', iJL 1897-98 `Uplift Tests for Roof Covering <br /> Systems' and FM 4470 Section 5.5 `Resistance to Foot Tra�c'. <br /> Code Compliance: The product described herein has demonstrated compliance with FBC <br /> 2014 Section 1507.4 <br /> Product Limitations: Design wind loads shall be determined for each project in accordance <br /> with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress <br /> design. The maximum fastener spacing listed herein shall not be <br /> exceeded. This product is not approved for use in the High Velocity <br /> Hurricane Zone. Fire classification is not within scope of this <br /> Evaluation Report. Refer to FBC 2014 Section 1505 and current <br /> approved roofing materials directory or ASTM E108/iJL790 report <br /> from an accredited laboratory for fire ratings of this product. <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.