3 15279.9 '009 W4-09 DSIE-1F471: GD2SP, �Gallery/Artistry/Expressions: 2" Double-skin Insulated EPS
<br /> � GR2SP, GD2LP, GR2LP, AR25P, (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-
<br /> � � .AR2LP, ED2SP, ED2LP, 4302, HDGC, Car(up to 9'0"wide) WINDCODEp W4 Garage Door
<br /> j '6202, SFC68, MFC68
<br />� :.._� .....__...._._.. .._�_-.. .._.-____.__._..__._...._....,_---- _.._ __-. .._------.._....�_____._.__�-.. ..__.___.___-.
<br />' Limits of Use Certification Agency Certificate
<br /> ; Approved for use in HVHZ: No FL15279 R4 C CAC Letter with proof of contract and oroof
<br /> Approved for use outside HVHZ:Yes of insoection.odf
<br /> ; Impact Resistant: No FL15279 R4 C CAC W4 Listinq Intertek.odf ,
<br /> � Design Pressure: +28 PSF/-29 PSF Quality Assurance Contract Expiration Date
<br /> i
<br /> Other:The standard glazing available for this product meets OS/21/2028
<br /> j the wind load requirements of the building code but DOES Installation Instructions
<br /> 'NOT meet the impact resistant requirement for windborne FL15279 R4 II 103969-B-Rev02.pdf
<br /> �debris regions. Verified By. Intertek Testing Services NA Inc. - ETL/Warnock
<br /> � Hersey °
<br /> Created by Independent Third Party: �
<br /> Evaluation Reports
<br /> Created by Independent Third Party:
<br /> -------___-_____.____.. ._-=--- - ---._....----- __-----------__...._.- --- _----------_----___ ---,
<br /> � 15279.10 �O10 W4-09 DSIU-iF171• 9200, Double-skin Insulated PUR(exterior skin 27 ga. min.; interior
<br /> 3 9201, 9203, HDP20, HDPF20, skin 27 ga. min.) Single-Car (up to 9'0"wide) WINDCODEOO
<br /> HDPL20, 7200, 7201, 7203, 8200, W4 Garage Door
<br /> �8201, 8203
<br /> �-____ _-----. _...-- -------_____ __
<br /> Limits of Use Certifcation Agency Certifcate '
<br /> � Approved for use in HVHZ: No FL15279 R4 C CAC Letter with oroof of contract and oroof �
<br /> Approved for use outside HVHZ:Yes of inspection.odf
<br /> Impact Resistant: N/A FL15279 R4 C CAC W4 Listinq Intertek.odf
<br /> Design Pressure: +28 PSF/-29 PSF Quality Assurance Contract Expiration Date j
<br /> Other:The OPTIONAL glazing available for this product OS/21/2028
<br /> i meets the wind load requirements of the building code but Installation Instructions
<br /> ;DOES NOT meet the impact resistant requirement for FL15279 R4 II 104183-Rev0l.pdf
<br /> ;windborne debris regions. The product without glazing DOES Verified By: Intertek Testing Services NA Inc. - ETL/Warnock
<br /> comply with the impact resistant requirement for windborne Hersey
<br /> ;debris regions (ref 1609.1.4 FBC). Created by Independent Third Party.
<br /> Evaluation Reports �
<br /> ' Created by Independent Third Party:
<br /> ! 15279.11 'O11 W4-09 DSIUO-1K479: Canyon Double Skin Insulated PUR(exterior skin 27 ga. min.; interior i
<br /> �Ridge/Brookstone skin 27ga. min.) with Overlay Single-Car (up to 9'0"wide)
<br /> WINDCODEp W4 Garage Door `
<br /> i
<br /> 'Limits of Use Certification Agency Certificate
<br /> � Approved for use in HVHZ: No FL15279 R4 C CAC Letter with proof of contract and oroof ;
<br /> ; Approved for use outside HVHZ:Yes of insoection.pdf
<br /> impact Resistant: N/A FL15279 R4 C CAC W4 Listinq Intertek.pdf
<br /> j Design Pressure: +28 PSF/-Z9 PSF Quality Assurance Contract Expiration Date j
<br /> ' Other:The OPTIONAL glazing available for this product OS/21/2028 ;
<br /> �meets the wind load requirements of the building code but Installation Instructions I
<br /> �DOES NOT meet the impact resistant requirement for FL15279 R4 II 104456-Rev0l.pdf �
<br /> j windborne debris regions. The product without glazing DOES Verified By• Intertek Testing Services NA Inc. - ETL/Warnock ;
<br /> ;comply with the impact resistant requirement for windborne Hersey
<br /> ;debris regions (ref 1609.1.4 FBC). Created by Independent Third Party:
<br /> Evaluation Reports
<br /> Created by Independent Third Party. j
<br /> p.�.._._...-'_'.. .._..__...._""' '_ '_..._.._...._..'-_.._...._....__...."""._....-"-'.. ..'_ ___""__'-'-' __..__ ._.._...__....'_'____...__�
<br /> �15279.12 �012 W4-09 PAN-2F151• 73, 1500, Steel Pan (min. 25 ga.) Single-Car (up to 9'0"wide) �
<br /> ; 75, 190, 84A, 94, 76, 42, 48, 55, WINDCODEOO W4 Garage Door
<br /> 42B, 48B, 555, 4RST, 6RST, 4RSF,
<br /> '6RSF, 2RST, GDSS, GDSSV, GR55,
<br /> j :GRSSV,ARSS, ARSSV, EDSS, EDSSV
<br /> ;Limits of Use Certification Agency Certificate
<br /> ; Approved for use in HVHZ: No FL15279 R4 C CAC Letter with oroof of contract and oroof ;
<br /> ; Approved for use outside HVHZ:Yes of ins�ection.pdf �
<br /> ! Impact Resistant: No FL15279 R4 C CAC W4 Listing Intertek.pdf
<br /> � Design Pressure: +25 PSF/-32 PSF Quality Assurance Contract Expiration Date ':
<br /> ; Other:The standard glazing available for this product meets OS/21/2028 �
<br /> 's the wind load requirements of the building code but DOES Installation Instructions �
<br /> NOT meet the impact resistant requirement for windborne FL15279 R4 II 300159-B-Revl6.pdf �
<br /> `debris regions. Verified By: Intertek Testing Services NA Inc. - ETL/Warnock �
<br /> Hersey
<br /> Created by Independent Third Party:
<br /> ; Evaluation Reports
<br /> ! Created by Independent Third Party:
<br /> � '
<br /> _ _..___ ------<--_---.._.. ._---._. ..-----...-.__.......---...----.. ----...------- ------.. ..�
<br /> �...._.._
<br /> � 15279.13 i 013 W4-09 PAN-2F441: G4S, GS4, Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.) Single- i
<br /> 'G4L, GL4, GD4S, GD4L, GR45, Car(up to 9'0"wide)WINDCODEOO W4 Garage Door �
<br /> ; (GR4L, G4SV, G54V, G4LV, GL4V, i
<br /> I !GD4SV, GD4LV, GR45V, GR4LV, E45,
<br /> { 'E4L, ED45, ED4L, E4SV, E4LV, !
<br /> ' �ED4SV, ED4LV, 554, SL4, AR45, �
<br /> 1 i AR4L, SS4V, SL4V, AR4SV, AR4LV i
<br /> �_. ..-----.. .
<br /> _.. .._.._____------------ -_ _- ---.. .._..-------------
<br /> �._._ _.__._.. .._.._------_..__.
<br /> I
<br />
|