My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
16-16439
Zephyrhills
>
Building Department
>
Permits
>
2016
>
16-16439
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/16/2017 1:41:24 PM
Creation date
2/16/2017 1:41:23 PM
Metadata
Fields
Template:
Building Department
Company Name
FLORIDA SENIOR PROPERTIES
Building Department - Doc Type
Permit
Permit #
16-16439
Building Department - Name
FLORIDA SENIOR PROPERTIES
Address
6701 DAIRY RD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> , . SECTION IV - SYSTEM DESIGN <br />' UL EX.3470 ULC CEx747 Page 4-� <br /> 4-1-06 REV.6 <br /> �� <br /> SYSTEM DESIGN GENERAL INFORMATION <br /> The ANSUL R-102 Restaurant Fire Suppression System may be 1.Nozzles must be located 2-8 in.{5-20 cm)into the center of the <br /> used on a number of different types of restaurant cooking appli- duct opening,discharging up.See Figure 1. <br /> ances and hood and duct configurations.The design information <br /> lis#ed in this section deals with.the limitations and parameters of <br /> this pre-engineered system.Those individuals responsible for the <br /> design of the R-102 system must be trained and hold a current �" <br /> ANSUL certi#icate in an R-102 training program_ <br /> The R-102 and the PIRANHA systems use compatible agents and <br /> components, therefore, they may be used together for cooking <br /> appliance, hood, and duct protection. The primary ANSIJL <br /> AUfOMAN Release can be either an R-102 or a PIRANHA <br /> AfVSUL AUTOMAN Release and can actuate up to two additional ..-=�� <br /> R-102 or PIRANHA Regulated Actuators. In systems utilizing a <br /> 101 remote rel�ase, any combina6on of ihe maximum Rumber of • <br /> regulated ac#uatbrs can be used. 2-8iN: <br /> cs—2o cm) �- <br /> � Both systems must actuate simultaneously. <br /> • Each system must be designed and installed.per its=appropri- FIGURE 1 <br /> ate manuaf. °0°"� <br /> m Adjacent appliances requiring protection must be protected 2•�n installations where a UL listed damper assembly is <br /> with the same type of system, either R-102 or PIRANHA, employed, the duct nozzle can be installec] beyond the 8 in. <br /> unless the center-#o-center spacing between the adjacent (20 cm) maximum,to a poini just beyond the damper assem- <br /> R-102 and PIRANHA nozzles is no less than 36 inches. bly that will not interfere with the damper.Exceeding the maxi- <br /> � When appliances are protected with R-102 nozzles, the hood mum of 8 in.(20 cm) in this way will not void the UL listing of <br /> and connecting duct above those appliances cannot be pro- the system. <br /> tected with PIRANHA nozzles. 3.Previously listed 3 flow number and 5 flow number duct pro- <br /> � Mixing systems in a common plenum is not aflowed. tection detailed in earlier published rrjanua�, Part No_418087- <br /> One of the key elements for restaurant fire protection is a correct ���n also still by utilized. <br /> system design.This section is dnrided inio ten sub-sections:fVoz- DUCT SIZES UP TO 50 IfV.(127 cm) <br /> �^ zle Placement Requirements,7ank Quantity Requirements,Actu- PERIMETER/16 tN_(41 cm)DIAMETER <br /> ation and Expellant Gas Line Requirements, Distribution Piping <br /> Requirements, Detection System Requirements, Manual Pull Sta- '• One 1 W nozzle(Part No.419336)=one flow number <br /> tion Requirements, Mechanical Gas Valve Requirements, Electri- . 50 in.(127 cm)perimeter maximum <br /> cal Gas Valve Requirements,Electrical Switch Requirements,and <br /> Pressure Switch Requirements. Each of these sections must be • 16 in.(41 cm)diameter maximum <br /> completed before attempting any installation. System design <br /> sketches should be made of ail aspects of design for reierence DUCT SIZES UP TO 100 IN.(254 cm) <br /> during installation. PERIMETER/32 IN.(81.3 cm) DIAMETER <br /> NOZLLE PLACEMENT RE�UIREMEIVTS • One 2W Nozzle(Part No.419337)-two flow numbers <br /> This section gives guidelines for nozzle rype, positioning, and • 100 in.(254 cm)perimeter maximum <br /> quantity for duct,plenum,and individual appliance protection.This � 32 in.(81.3 cm)diameter maximum <br /> section must be completed before determining tank quantity and . A 2WH nozzle (Part No.78078) must be substituted for a 2W <br /> piping requirements. nozzle for any installation using Option 2 of the 1.5 gallon sys- <br /> Duct Protection-Single(doale' tem coverage(duct and plenum protection only).A 2WH noale . <br /> All duct profection is UL listed wi�out limitation of maximum duct �s limited to a maximum of 75 in.{190 cm)perimeter or a maxi- <br /> length (unlimited length).This includes all varieties of ductvuorks mum diameter of 24 in_(61 cm}of coverage. <br /> both horizontal and vertical including ducis that run at angles to fihe chart below shows the maximum protection available from <br /> the horizontal and ducts with directional bends_ each duct nozzle_ <br /> The R-i 02 system uses different duct nozzles depending on the Part 3.0 Gallon 1.5 Gallon <br /> size of duct being protected. Description No. System System <br /> ' ' 2W Nozzle 419337 Maximum Maximum <br /> 100 in.(254 cm) 100 in.(254 cm) <br /> Perimeter Perimeter <br /> ► 1 W Nozzle 419336 Maximum Maximum <br /> - 50 in.(127'cm) 50 in.(127 cm) <br /> Perimeter Perimeter <br /> ,.� <br />
The URL can be used to link to this page
Your browser does not support the video tag.