Laserfiche WebLink
.� <br /> �_. „� � � <br /> � <br /> - �f�ii�lll��E��: <br /> TABLE 1G WOOD DECKS-NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVER <br /> SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED ROOF COVER <br /> Thermal Barrier RoofCover <br /> System Roof Deck MDP <br /> No. Type Attach Membrane Fasteners Fastener �P Wjdth Lap Spacing Seam Weld (psf) <br /> Spacing <br /> Min.19/32-inch thick Mule-Hide fR Deck <br /> Panel A or C or Barrier Technology Corp (Optional)Any Mule-H1de EHD 1.5-inch <br /> W-5 "Blazeguard A or C"at max.24-inch spans approved Loose-laid Mule-Hide TPO-c Fasteners and 12-inch o.c. "5-inch 48-inch o.c. outside -30.0 <br /> attached using No.8 x 2Y:-inch long thermal barrier 2.4 Seam Plates <br /> course thread screws spaced 6"o.c. <br /> Min.19/32-inch thick Mule-Hide FR Deck <br /> Panel A or C or Barrier Technology Corp (Optional)Any Mule-Hide EHD 1.5-inch <br /> W-6 "Blazeguard A or C"at max.24-inch spans approved Loose-taid Mule-Hide TPO-c Fasteners and 6-inch o.c. 5-fnch 72-inch o.c. outside 52.5 <br /> attached using No.8 x 2�-inch long thermal barrier 2.4 Seam Piates <br /> course thread screws spaced 6"o.c. <br /> MIn.19/32-Inch thick Mule-Hide FR Deck <br /> Panel A or C or Barrier Technology Corp (Optional)Any Mule-Hide EHD 1,5-inch <br /> W-7 "Blazeguard A or C"at max.24-inch spans approved Loose-laid Mule-Hide TPO-c Fasteners and 6-inch o.c. 5-inch 48-inch o.c. outside -�5.0 <br /> attached using No.8 x 2%:-inch long thermal barrfer 2.4 Seam Plates <br /> course thread screws s aced 6"o.c. <br /> Mfn.19/32-inch plywood at max.24-inch (Optional)Any Mule-Hide EHD 4&inch o.c.(over iS-inch <br /> W-S spans attached usfng 8d ring shank nails approved Loose-laid Mule-Hide TPO-c Fasteners and 6-inch o.c. 5.5-inch structural members) outside -�5.0 <br /> spaced 6-Inch o.c. thermal barrier 2.4 Seam Plates <br /> TABLE 1D:WOOD DECKS—NEW CONSTRUCTION <br /> SYSTEM NPE F:NOiV-INSULATED,BONDED ROOF COVER <br /> System Roof Cover MDP <br /> Roof Deck <br /> No• Membrane Appliwtion (Psfl <br /> W 9 Min.15/32-inch thick Mule-Hide FR Deck Panel A or C or Barrier Technology Corp"Blazeguard A or C"at Mule-Hide TPO-c WBBA 2000 -45.0 <br /> max.24inch spans attached using No.8 x 2Y-inch long course thread screws spaced 6"o.c. <br /> W-10 Min.19/32-inch thick Mule-Hide FR Oeck Panel A or C or Barrier Technology Corp"Blazeguard A or C"at Mule-Hide TPO-c WBBA 2000 -52.5 <br /> max.24-inch spans attached using No.8 x 2�-inch long course thread screws spaced 6"o.c. <br /> Exterior Research and Design,LLC.d/b/aTriniry�ERD Evaivation Report MI5060.06.09-R3 for FLi2772-R3 <br /> Cerdflcate of Authorizatlon q9503 Revision 3:03/18/2015 <br /> Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 4 of 18 <br /> 1 ) ) <br />