Laserfiche WebLink
FORM R405-2014 <br /> FLORIDA E�IE��Y EFFICIEI�GY CODE FOR �UILDI�V� CONSTRUCTIOfV <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Driftwood 6 plex Builder Name: lt.y Y✓�C-�l CMS"���"" �-�'�� <br /> Street: (a�4 a P)0.�V��d ��f�{� Permit Office: Pasco <br /> City,State,Zip: Zephyrhills,FL, 3��jt{Z Permit Number: ��pq�� <br /> Owner: Driftwood of Zephyrhills Jurisdiction: <br /> Design Location: FL,Tampa <br /> 1. New construction or existing New(From Plans) 9. Wall Types(4806.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Multi-family a.Concrete Block-Int Insul,Exterior R=5.0 3186.00 ft2 <br /> b.Frame-Wood,Exterior R=11.0 1620.00 ft <br /> 3. Number of units,if multiple family 1 c.N/A R= ft� <br /> 4. Number of Bedrooms �2 d.N/A R= ft2 <br /> 5. Is this a worst case? No 10.Ceiling Types (7218.0 sqft.) Insulation Area � <br /> a.Under Attic(Vented) R=30.0 7218.00 ft <br /> 6. Conditioned floor area above grade(ftZ) 7218 b.N/A R= ftx <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(531.6 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Garage 6 90 <br /> a. U-Factor: Dbl,U=0.30 279.58 ftZ <br /> SHGC: SHGC=0.26 <br /> b. U-Factor Dbl,U=0.32 252.00 ft� 12.Cooling systems kBtulhr Efficiency <br /> SHGC: SHGC=0.24 a.Central Unit 87.0 SEER:14.00 � <br /> c. U-Factor: N/A ft2 ' <br /> i <br /> SHGC: 13.Heating systems kBtu/hr Efficiency ' <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 87.0 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.G00 ft. <br /> Area Weighted Average SHGC: 0.251 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (7218.0 sqft.) Insulation Area EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 7218.00 ft2 b. Conservation features <br /> b.N!A R= ftz None <br /> c.N/A R= ftZ 15.Credits CF,Pstat <br /> Total Proposed Modified Loads: 161.50 �p C c <br /> Glass/Floor Area: 74 Total Baseline Loads: 172.69 �1���� <br /> I hereby certify that the n a d specifications covered by Review of the plans and �+�Z'�E��'A�.�, <br /> this calculation are in � li nce�with the Florida Energy specifications covered by this �y ,�� r�^ �� 0,�, <br /> Code. � calculation indicates compliance �w`�i,, ' n_�,o�` <br /> � � with the Florida Energy Code. E- rm1,�.,''4•.;: ,,�:�•.��°„�O <br /> � � --.:'�� <br /> PREPARED BY: �' " � Before construction is completed �. ti ����"'� d <br /> DATE: �' this building will be inspected for � ��ji" � <br /> compliance with Section 553.908 * �{� �' � <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. � <br /> with the Florida Energy� ���D W'E"��� <br />' OWNER/AGENT:�� BUILDING OFFICI L: �� <br /> DATE: �`Z� '��' DATE: 'd <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2:1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope I�akage , <br /> test report in accordance with R402.4.1.2. <br /> - Compiiance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. <br /> 1/26/2016 8:09 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />