Laserfiche WebLink
r <br />� . r■u..■. .�vt■.v�.a <br /> - Site Preparatlon <br /> POCKET PENETROMETER TEST X <br /> '� Debris and organfc material removed <br /> . The pocket penetrometer tests are rounded down to�psf Water drainage:Natural X Swale Pad Other <br /> or check here to declare 1000 Ib. soil without testing. <br /> X l�� X�� X�� Fastenlna multi wide units <br /> Floor: Type Fastener: Length; Spacinq: <br /> � ' Walis: Type Fastener: Len�th: Spacing: <br /> POCKET PENETROMETER TESTING METHOD Roof: Type Fastener: Length: Spacing: <br /> For used homes a min.30 gauqe, 8"wide, galvanized metal strip <br />, 1, Test the perimeter of the home at 6 locations. will be centered over the peak of the roof and fastened with galv, <br /> roofing nails at 2"on center on both sides of the centerline, <br />'� 2. Take the reading at the depth of the footer. <br /> G8Sk0t(weatherarooflna reaul�ementl <br /> 3. Using 500 Ib, increments,take the lowest <br />', reading and round down to that increment. I understand a properly installed gasket is a requfrement of all new and used <br /> homes and that condensation, mold, meldew and buckled marriage walls are <br /> `,1�� a result of a pooriy installed or no gasket being installed, I understand a strip <br /> X X �Q X <<O(�j of tape will not serve as a gasket. <br /> Installer's initials <br /> TORQUE PROBE TEST <br /> _ Type pasket Installed: <br /> The results of the torque probe test is inch pounds or check Pg, Between Floors Yes <br /> here if you are declaring 5'anchors without testing . A test Between Walls Yes <br /> showing 275 inch pounds or less will require 5 foot anchors. ' Bottom of ridgebeam Yes <br /> Note: A state approved lateral arm system is being used and 4 ft, <br /> - anchors are allowed at the sidewall locations. I understand 5 ft weatherprooting <br /> anchors are required at all centerline tie points where the torque test <br /> reading is 275 or less and where the mobile home manufacturer may The bottomboard will be repaired and/or taped. Yes X . Pg. <br /> requires anchors with 4000 Ib holding capacity. Siding on units is installed to manufacturer's specifications, Yes X <br /> LLE Installer's initials Fireplace chimney installed so as not to allow intrusion of rain water. Yes,� <br /> ALL TESTS MUST BE PERFORMED BY A LICENSED INSTALLER Mlscellaneous <br /> Installer Name Lionel Easler Skirting to be installed. Yes X No <br /> Dryer vent installed outside of skirting. Yes N/A X <br /> Date Tested 2/1/2016 Range downflow vent installed outside of skirting. Yes N/A�_ <br /> Drain lines supported at 4 foot intervals, Yes X <br /> Electrical crossovers protected. Yes NA <br /> Other; <br /> Electrical <br /> Connect electrical conductors between multi-wide units,but not to the main power <br /> source. This includes the bonding wire between mult-wide units. Pg.�_ Instailerverifies all information given wlth this permit worksheet �i <br /> um na is accurate and true based on the <br /> - manufacturer's installation instructions and or Rule 15C-1 &2 <br /> Connect all sewer drains to an existing sewer tap or septic tank. Pg. <br /> Installer Signature Date 2�8�2016 <br /> Connect all potable water supply piping to an existing 'water meter,water tap, or other _ <br /> independent water supply systems. Pg. <br />