My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
16-17092
Zephyrhills
>
Building Department
>
Permits
>
2016
>
16-17092
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/20/2017 10:23:18 AM
Creation date
2/20/2017 10:16:09 AM
Metadata
Fields
Template:
Building Department
Company Name
GRAND HORIZONS
Building Department - Doc Type
Permit
Permit #
16-17092
Building Department - Name
KYPER,JAMES 7 SHERRI
Address
7902 KAY MARIE AVE LOT 309
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECTION 11 —MISCELLt�N�+OUS AND FINAL INSPEC'I'IONS Indez <br /> 11.1. �W1V�NG, CARPORTS, PORC�IE5, UTILITY ROOMS, ETC. <br /> Additional stntctures such as awnings, carports, patio covers or attachments to a Palm <br /> Harbor Home have not typically been taken into consideration nor calculated into the <br /> design for roof or wind loads. Any additions made to the home must be self-supporting <br /> and shall not interfere with weatherproofing(i.e. shingles,flashimg,gutters, siding). <br /> However, some Pa1m Hazbor homes have an option to be ordered with a factory installed <br /> receiver designed to take the loads of an add-on. In this case,refer to the detail for <br /> infonnation on specific 'S�-I�6�1A1i—��rur@i3'iCii+ • FACTORY INSTALLED DOUBLE SECTION HOME <br /> PERIMETER PIEF2S AND FOOTERS �` RECEIVER '� _,�/ <br /> AWNING(BY OTHERS)—�� �..` f� i �-�_ <br /> AVIMING UNIT LOAD�SPACIfVG SITE INSTALLED <br /> 1MDTH WIDTH 8'-0"o.c. FOR gY OTHERS� � <br /> 16 x 16 SITE INSTALLED '� qy�/NING WIDTH <br /> �� 16'-0'MAX.-WL-1 166"MAX. 1 B6"MAX. <br /> �Z 140"I 160" 4440# 5-3" i UNR WIDTH UNIT WIDTH <br /> 180" 4788# S-9" � ' � . 1 ) { <br /> i 16'-0'AAAX.-1M1rL� <br /> 16' 140"/160' 4886# S-T' j BY OTHERS � ~ <br /> 180" 5236# S-2 <br /> ��\ <br /> - - �� - p�-� - - � ,:n - �.y;. _ .:•a - ni r:f � � -i— <br /> 140'I 160' S334# S-1" I / <br /> 20' 180" 5684# 4'-9" �, � <br /> �� �� �`` . <br /> 8'MNCIMUM �� WZ2&3REQUIRETIE-DOWN <br /> INSET � EN6INEERING VECTOR SYSTEM(OR <br /> Perimeter piers and footer notes: WZ 283 REQUIRE EQUAL)OR ANY QUALIFYING SYSTEM <br /> 30" ! A�CHOR AtdD ;%SPECIFICALLY APPROVED FOR PALM <br /> 1. Spacing for 16 x 16 is based on �<;,:: VERTICAL TIE HARBOF2 HOMES <br /> 2000 psf soil bearing capacity. �5��°�.c.�". <br /> 2. Refer to palm harbor homes �1 DIANGONAL TIE AND ANCHOR <br /> WITH STABILIZER�6'-0'O.C.AAAX. - <br /> installation manual for footers °'. .`°; <br /> re uired for the loads ven '���-.`�`: �—��� `�::`'. ��� <br /> q gi @ I I I—� �• I I I <br /> 8'-0" o.c. c=1I I��—T�I I I I I��� <br /> �=1T��y- <br /> Notes: u �Tf� <br /> 1. Vertical tie connections have been factory installed to handle the <br /> uplift and overturning load from the main unit along with the additionalload from the awning <br /> connection to the main unit. (brackets @ 5'-4" o.c. max.) <br /> 2. The factory installed receiver is designed to handle the additional uplift and downward loads <br /> from the connection of the awning to the main unit. <br /> 3. The awning soof and roof support away from the main unit must be designed(by others)to <br /> carry all loads to the ground. The design of the awning connection along with weatherization <br /> (by otheis)must be designed to carry the appropriate load into the factory-installed receiver. <br /> The design must be according to the loads and requirements ofthe IRC 2003 for exposure'c'. <br /> 4. Factory installed members were designed for awning loads based on 90 mph(3 second gust) <br /> winds for wind zone 1, 120 mph(3 sec. gust)winds for wind zone 2, and 140 mph(3 sec. <br /> gust)winds far wind zone 3. This is in accordance with IRC 20U3, exposure 'c'. <br /> 5. For approved lateral load resisting systems'install�tion requirements and number required, <br /> refer to other pages in the Pa1m Harbor Homes installation manual. <br /> 6. No stabilizer plates aze required at anchors loaded in direct(in-line)pull. <br /> 7. This design is for 140" minimum floor width and 186" maximum floor width on the main <br /> units and for 20 psf roof live load in all wind zones. ', <br /> 8. Maximum pier height including I-beam for wind zone 1 is 52"and minimum height is 31". � <br /> Pier heights for wind zones 2 and 3 are based on eector system design. <br /> Section 11,Misc &Final Inspection Page 1 COPYRIGHT�2006 BYPALM HARBOR HOMES,INC. � <br /> All Rights Reserved. I <br />
The URL can be used to link to this page
Your browser does not support the video tag.