Laserfiche WebLink
Manual J Winter Caiculations <br /> Residential Load - Component Details (continued) <br /> BOOMHOWER Project Title: <br /> 6131 19TH ST BOOMHOWEWR RES ADD MJ TJLII 3-16 <br /> ZEPHYRHILLS, FL 33541 Building Type: User <br /> ORIENTATION EAST HVAC VALUES SEMI TIGHT 3/14/2016 <br /> Coniponent Loads.for;Roo�ri`#�2:.FAMILY;ROOM At3D' _�_-�:�. � °- _:, :=,',:--:� -; ' '�.= ;:`.":_.�_�:� � , .. :.., _;.-� <br /> Window PaneslT Frame U Orienta6on Area X HTM= Load <br /> 2 1, NFRC 0.16 vnyl 0.33 W 16.9 11.2 190 E�t�st� <br /> 3 1, NFRC 0.16 Vnyl 0.33 S 33.9 11.2 380 Btuh <br /> �ndow Total 50.8 570 Btuh <br /> Walls Type Omt. Ueff. R-Value Area X HTM= Load <br /> (Cav/Sh) <br /> 3 Conc BIk,Hollow -Adj (0.132) 5.0/0.0 32 4.47 143 Btuh <br /> 4 Frame-Wood -Int (0.089) 13.0/0.0 39 3.02 117 Btuh <br /> 5 Frame-Wood -Int (0.089) 13.0/0.0 19 3.02 56 Btuh <br /> 6 Frame-Wood -Int (0.089) 13.0/0.0 88 3.02 266 Btuh <br /> 7 Conc BIk,Hollow -Ext (0.132) 5.0/0.0 87 4.47 389�t�h <br /> 8 Conc BIk,Hollow -Ext (0.132) 5.0/0.0 74 4.47 332�.�..h <br /> Wall Total 339 1303 Btuh <br /> Doors Type Storm Ueff. Area X HTM= Load <br /> 3 Wood-Exterior, n (0.570) 20 19.4 388 Bt��h <br /> Door Total 20 388E�tuh <br /> Ceilings Type/Color/Surtace Ueff. R-Value Area X HTM= Load <br /> 2 Verited AttiGUShing (0.032) 30.0/0.0 220 1.1 238 Btuh <br /> Ceilin Total 220 238Btuh <br /> Floors Type Ueff. R-Value Size X HTM= Load <br /> 2 Slab On Grade (1.180) 0.0 58.0 ft(perim.) 40.1 2327 Btuh <br /> Floor Total 220 2327 Btuh <br /> Room Envelope Subtotal: 4826 Btuh <br /> Infiltrdtion Type Wholehouse ACH Room Volume Wall Ratio CFM= r <br /> Natural 0.84 1760 0.23 24.4 911 Btuh <br /> Duct load Av�qe sealed,Supply(R6.0-Attic),Retum(R6.QAttic) (DLM of 0.103) 592 E�xuh <br /> Room#2 Sensible Room Subtotal 6328 Btuh II <br /> . . ... ... .. . ..... : .. :.:• :.-_: - .. _; .;..--,,.� ... .. _ - - - - _ <br /> .. : ... ....: . :::.: .�..., ...,, .. . ... ._ - <br /> . . _,;._::=, - � <br /> Compor�ent.Loads fac Room#3:STORAGE.,�►Dp`:�;�', � --: - - : _ - ,- ° _ {�� <br /> - - - �J <br /> Ceilings Type/ColodSurFace Ueff. R-Value Area X HTM= Load <br /> 3 Vented Attic/UShing (0.049) 19.0/0.0 132 1_7 220 Eci�:h <br /> Ceilin Total 132 220Btuh <br /> Floors Type Ueff. R-Value Size X HTM= Load <br /> 3 Slab On Grade (1.180) 0.0 46.0 ft(perim.) 40.1 1846 Bt��h <br /> Floor Total 132 1846 6:t+h <br /> EnergyGauge�/USRCZB v4.0 Page 2 <br />