Laserfiche WebLink
FORM R405-2014 . , • ' . <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONST�UCTION <br /> � Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: BOOMHOWEWR RES ADD EPI TJLI13-16 Builder Name: CUNNINGHAM CONSTRUCTION <br /> SVeet: 6131 19TH ST Permit Ofi'�ce: ZEPHYRHILLS <br /> City, State, Zip: ZEPHYRHILLS,FL,33541 Pertnit NumberN�c f'��Z3 <br /> Owner: BOOMHOWER Jurisdic�ar. 611600 . <br /> Design Lor tion: FL, Tampa <br /> 1. New c�nstruction or e�dsting Addibon 9. Wall Types(1137.3 sqft.) Insulatior Area <br /> 2. Single family or muttiple Tamity Single-famity a•Con�e Black-�nt I�uul, 6derior R=5.0 840.00 Rz <br /> b. Interior Frame-Waod,Interior R=13.0 145.33 f� <br /> 3. Number of units,ff muttiple famity 1 c. Frame-Wood,Adjacent R=11.0 120.00 ftz <br /> 4. Number of Bedroort�(Bedrms In Addition) 2(0) d• °������) R= 32.00 ft� <br /> 5. Is ihis a worst case? No 10. Ce�Ting Types(1072.0 sqft.) Insulation Ar� <br /> a.Under Attic(Vented) R=30.0 940.00 fl <br /> 6. Conditioned floor area above grade(ft� 940 b. Under Attic(Vented) R=1.0 132.00 ft <br /> Conditioned floor area below grade(R� 0 c.WA R= ftz <br /> 11.Duds R � <br /> 7. Windows(97.1 sqft.) Description Area a.Sup:Attic,Ret Attic,AH:Attic 6 188 <br /> a. U-Factor: Sgl, U�.33 97.06 RZ <br /> SHGC: SHGC=0.76 <br /> b. U-Factor: WA � 12• Cooling systems kBtulhr Efficiency <br /> SHGC: a.Central Unit 23.6 SEER:11.00 <br /> c. U-Factor: WA fi� <br /> SHGC: 13. Heating systems kBtWhr Ffficiency <br /> d. U-Factor. N/A ft a. Electric H�t Pump 23.6 HSPF:7.20 <br /> SHGC: <br /> Ar�Weighted Aver-dqe Overhang Depth: 1.185 ft. <br /> Area WeigMed Average SHGC: 0.160 14. Hot water systems- Replacement equipment <br /> 8. Floor Types (1072.0 sqft.) Insulation Ar� a" �� �=•�ga�lons <br /> a. Slab-On-Grade Edge Insufatian R=0.0 1072.OD ft�F:0.920 <br /> b. Conservation f�tures <br /> b.WA R= fi� None <br /> c.WA R= ft 15 Credits None <br /> Glass/FloorArea: 0.103 Total Proposed Modified Loads: 35.85 PA�� � <br /> Total Baseline Loads: 35.85 <br /> -F"-'-�:,�."-�,� <br /> I hereby certify that the plans and specifications covered by Review of the plans and ����;f1E STA� <br /> this calculation are in compliance with the Florida Energy specifications covered by this ..��Y� �"'�'�°=�G�p� <br /> :.. .,.<> <br /> Code. calculationindicatescompliance r�'���;,;T? ==:�:�f� <br /> with the Florida Energy Code. ���:��,:.,:�,,'; '-`-:�:�''..•�'�'- p� <br /> PREPARE "'� Before construction is completed tr.�t-.�`a`""i�=�,"„"���=�'=j <br /> �.,.�;..;,-��:.�=;�,`r_; <br /> DATE: this building will be inspected for ��� ;, . ;�� <br /> � compliancewith Section 553.908 �'� ��= ti'�" ' ' �`' <br /> `�'r ' '"`3'r � /' <br /> Florida Statutes. �-=-� a <br /> I hereby certify that this building,as designed,is in compliance ,! c�a���._��y-C�J <br /> with the Florida Energy C . � , �pDµ,����� <br /> / ``--;�.-�==. <br /> DATEE��/�y'��l �o � ����/ DATE:�NGOFF CIAIr: <br /> - Compliance requires certlfication by the air handler unit manufactur+er that the air handler enclosure qualifies as <br /> certified factory�sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an env�lope leakage <br /> test report in accordance with R402.4.1.2. <br /> 3/14/201612:01 PM EnergyGauge� USA- FlaRes2014 Section R405.4.1 Compliant SoTtware P�e 1 of 5 <br />