Laserfiche WebLink
i 'TABLE 4d2A , ALL CLIMATE ZONES � <br /> BllIL.DING COMPONENT PERFORMARlCE CRITERtA iNSTALLED VALUES <br /> Windows : • lJ-Factor< 0.65 iJ-Factor= <br /> SHGC= 0.30 SHGG= - <br /> %ofCFA<20 % %ofCFA= <br /> Sk li hts U-factor{0.75 U-factor= <br /> Boors: Exterior doar U-factar U-factor<0.65 U-factor: � <br /> Floors: <br /> Slab-on-Grade No requirement <br />� Over unconditioned s aces3 R-13 R-Value= <br /> Walls—Ext. and Adj. <br /> Frame R-13 R-Value= <br /> Mass 3 <br /> Interior of wall: R-7.8 Ft-Value= <br /> E�cteriar of wa{I f2-6 R-Value= <br /> Ceilings : R=3Q R-Value= Test repart <br /> Reflectance 0.25 Reflectance= Attached? YeslNo <br /> Air distribution system <br /> Ductwork&air handling unit: Location: <br /> llnconditianed space Not allowed <br /> Condi#ioned space <br /> Duct R-value R-value?R-6 R-Value= Test report <br /> Air leaka e Q� C1„ s 0•03 Q� = Attached? Yes/No <br /> Air canditionin s stems SEEF2=13A SEER= <br /> Fieating system <br /> Heat pump5 Coaling: SEER= 13.0 S�ER= <br /> Heating: HSPF= 7.7 HSPF= <br /> Gas fUmace AFUE_�$°lo AFUE_ <br /> Oil furnace AFUE=78°lo AFUE= <br /> Electric resistance: Nat allowed5 <br /> Wafer heatin�system(storage type): <br /> Electric : 40 gal:EF=0.92 Gailans= <br /> 50 gal: EF=Q.90 EF= <br /> Gas fireds 40 gal: EF=0.59 GaUons= <br /> 50 gal: EF=0.58 EF= .. <br /> Other describe : <br /> (9)Each componeni present in the As Proposed hame must rneet or exceed each of the applicable performance criferia in order to comply with this <br /> code using this method;otherwise Section 405 compliance must be used. <br /> � (2}Windows and daors quaiifying as glazed fenestration areas must comply with both the maximum U-Factor and the maximum SHGC(solar Heat <br /> Gain Goefficient)criteria and have a,maximum total window area equa!to or less than 20%of the conditioned 8aor area{CFA};otherwise Sectian <br /> 405 must be used for compliance. <br /> �xceptions:�Additions af 600 square feet(56 m2}or less may have a maximum glass to CFA of 50 percent. �-I�eaeva�ieas-wit4�ew-wiadews <br /> .^�'^��,,,���ar�gu�ese-�ae�edg..���„u r�g�a�r-i�ave-4in4ed-�1a�i�-er-�et�te-pa�te-s3ea� <br /> g{a�i�g;-Re�laserr�e � s-s�iall�e-deN�4e-�aa�-oF-si�gle-Saa�ed-wit#�-a-di##�s� <br /> (3}R-values are for insulation material only as applied in accordance with manufacturers'insta(lation instructians.For mass wa�ls,the"interior of walP' <br /> requirement must be met exce t if at least 50°10 of the E2-6 insulation required for the"exterior of wall"is insEailed e�erior of,ar integrai to,the wal(. <br /> (4)Ducts&AHU installed substantially leak free per Section 403.2.2,1 Test by Class 1 BERS rater required. <br /> Exception:Llucts installed anto an existing air disfributian system as part of an addition or renovation;duct must be R-6 installed per Sec.503.2.7.2. <br /> {5}For al!convenEiona!units with capacities greater than 30,000 Btuthr. Far other types of equipment,see Tables 503.2.3(9-8�8}. <br /> Exception:Electric resistance heat prohibition does not apply to additions,renovations,and new heating systems installed in existing buildings. <br /> 6 For other eiectric stora e voiumes,min.EF=0.97- 0.00132*vo(ume ;for other natural as stora e volumes,min.EF=0.67- 0.0019*volume <br /> TABLE 4028 MANQATORY REQUIREMEN7S <br /> Com onen# Section Summar of Re uirement s Check <br /> Air leakage 402.4 To be caulked,gasketed,weatherstripped or otherwise sealed.Recessed lighting IC- <br /> rafed as meeting ASTM E 283.Windows and doors 5 0.30 cfm/sq.ft.Testing or visual <br /> ins ection re uired.Fire laces: asketed doors&outdoar combus#ion air. <br /> Ceilin slknee walls 405.2.1 R-'19 s ace ermittin . - <br /> Pro rammable thermosta# 403.1.1 Where farced-air furnace is rima s stem, ro rammable thermostat is re uired. <br /> Air distribution system 403.2 Ducts in attics or on roofs insulated to R-8;other ducts R-6. Ducts not in conditioned <br /> s ace tested to Qn=0.03 b Class 1 BERS rater. <br /> Water heaters 403.4 Nea#trap required far vertical pipe risers.Camply with efficiencies in Table 403.4.3.2. <br /> Provide switch or clearly marked circuit breaker(electric)or shutoff {gas}.Circulating <br /> s stem i es insulated to>R-2+accessible manual OFF switch. <br /> Swimrning pools&spas 403.9 Spas and heated poofs must have vapor-retardant covers or a liquid cover or other <br /> means proven ta reduce heat bss except if 70°l0 of hea#from site-recovered energy; <br /> � vvher�99e�--�-��eel�eve�.Off/timer switch required.Gas heaters minimum thermal <br /> efficienc =78°/a 82%after 4/16/13 . Heat um ool heaters minimum COP=4.0. <br /> CaolingJheating equipment 403.6 Sizing ca(culatian performed&attached. Minimum efficiencies per Tables 503.2.3. <br /> Equipment efficiency veri�ication required.Special occasion cooling ar heating capacity <br /> requires separate system or variable capacity system.Electric heat>10kW must be <br /> � divided into iwa or more sta es. <br /> � - - - <br />