My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
16-17305
Zephyrhills
>
Building Department
>
Permits
>
2016
>
16-17305
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/20/2017 11:57:49 AM
Creation date
2/20/2017 11:56:35 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVER OAKS VILLAGE
Building Department - Doc Type
Permit
Permit #
16-17305
Building Department - Name
VANDERBILT,MICHAEL D
Address
6437 ASHVILLE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Vanderbilt Model Builder Name: <br /> Street: Ashville Drive Permit Office: Pasco <br /> City,State,Zip: Zephyrhills,FL, Permit Number� <br /> Owner Ryan Vanderbilt Model Jurisdiction: <br /> Design Location: FL,Tampa <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2603.5 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=5.0 1703.50 ftZ <br /> b.Frame-Wood, Exterior R=13.0 900.00 ftZ <br /> 3. Number of units,if multiple family 1 c.N/A : <br /> R= ft <br /> 4 Number of Bedrooms 2 d.N/A R= �z <br /> 10.Ceiling Types (843.0 sqft.) Insulation Area <br /> 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 843.00 ft2 <br /> 6. Conditioned floor area above grade(ftZ) 1325 b.N/A R= ftZ <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ftZ <br /> 11.Ducts R ft� <br /> 7. Windows(119.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 200 <br /> a. U-Factor: Dbl,U=0.30 119.00 ftZ <br /> SHGC: SHGC=0.26 <br /> b. U-Factor N/A ft� 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: a.Central Unit 30.0 SEER:14.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 30.0 HSPF:8.20 <br /> SHGC� <br /> Area Weighted Average Overhang Depth: 1.000 ft. <br /> Area Weighted Average SHGC: 0.260 14 Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (843.0 sqft.) Insulation Area EF.0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 843.00 ftZ b. Conservation features <br /> b.N/A R= ftz None <br /> c.N/A R= �Z 15.Credits CF,Pstat <br /> Glass/Floor Area: 0.09 <br /> Total Proposed Modified Loads: 54.80 pASS <br /> Total Baseline Loads: 54.58 <br /> I hereby certify that the nd�pecifications covered by Review of the plans and p�'fHE�7'.��.� <br /> this calculation are in com a c it�i the Florida Energy specifications covered by this �y ,��`�•'" _ �`, p� <br /> Code. \ calculation indicates compliance �`�,,, '' 'z:;���.•> >rc~ <br /> / with the Florida Energy Code. � lu,,��,��,:�-�:.;;:;.�;.••;;:.��„�O <br /> PREPARED BY: ` � Before construction is completed u� � � " <br /> DATE: this building will be inspected for � 1;-�j,p;�� � � <br /> AJ�,JIy � <br /> compliance with Section 553.908 * �,-� � <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. �� ��, <br /> with the Florida Energy ode � � �j� �''O,p+4y��� <br /> OWNER/AGENT: BUILDING OFF IQL: /� <br /> DATE. ��Z�� �� DATE: 5 <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. <br /> 3/8/2016 11:32 AM EnergyGaugeOO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.