Laserfiche WebLink
1 <br /> - FORMS ' <br /> TABLE402A I <br /> BUIL�ING COMPONENT PERFORMANCE CRITERIA' INSTALLED VAW E5: �I <br /> U aclor<0.65 U-Faclor= '� <br /> Windows(see Note 2): HGC=0.30 <br /> /otCFA<=20% SHGC= � <br /> Sk li hls U-Factor<0.75 %ol CFA= <br /> Door;:[xierior door U-Facfor U-Factor<0.65 �• U-Faclor= <br /> Floors: Slab-on-grade No requirement iR-Value= <br /> Over uncondilioned s aces see Note 3 R-13 1 <br /> Walls—Ext.and Adj.(see Nole 3): �� <br /> Frame R-13 R-Value= <br /> Mass (see Note 3) <br /> Interior ol walL � " R-7.8 R•Value= <br /> Exterior of wall: R-6 R alue= <br /> Ceilings(see Notes 3&4) Fi=30 R- alue= Test report <br /> Reflectance 0.25 R tleclance= Allached7 <br /> Yes/No <br /> , Air distribution syslem(see Note 4) <br /> Ductwork&al�handling unit: Lo ation: <br /> Unconditioned space Nol allowed Test repoA <br /> Condilioned space Attached7 <br /> Duct R-value R-value 2 6 Yes/No <br /> R alue= <br /> Air leakage�n Qn 5 0.03 Q _ <br /> Air conditionin s slems see Nole 5 SEER=13.0 S ER= <br /> Heating system <br /> Heat pump(see Note 5) Cooling: SEER=13.0 S ER= <br /> Heating: HSPF=7.7 SPF= <br /> Gas furnace AFUE 78% FUE_ <br /> Ojl furnace AFUE 78% AFUE_ <br /> Electric resislance:Not allowed(see Nole 5) <br /> Waler heeling system(storage type) <br /> Eleclric(sea Nole 6): �0 gal:EF=0.92 Gallons= <br />' S�'�•al:EF=0.90 EF= <br /> Gas fired(see Note 7): 40 g�I:EF=0.59 Gallons= <br /> Olher(describe): 50 gal:EF=0.58 � EF= <br /> (1)Each component present in the As Proposed home must meet or exceed e of the applicable perf ance criteria in orderto compiy with this code using this method; <br /> otherwise Section 405 compliance must be used. <br /> (2)Windows and doors qualifying as glazed fenestration areas must comply with both the maximum U-Factorand the maximum SHGC(solarHeat Gain Coefficient)criteria <br /> and have a maximum total window area equal to or less than 20%of the conditioned floor area(CFA);othenvise Section 405 must be used for compliance. <br /> Exception: Additions of 600 square feet(56 mZ)or less may have a maximum glass to CFA of 50 percent. <br /> (3)R-values are for insulation material only as applied in accordance with manufacturers'installation instructions.For mass walls,the"interior of wall"requirement must be <br /> met except if at least 50%o(the R-6 insulation required for the"exterior of wall"is installed exterior of,or integral lo,the wall. <br /> - (4)Ducts 8 AHU installed substantially leak free per Section 403.2.2.1 Test by Class 1 BERS raler required. <br /> Exception:Ducts installed onlo an existing air distribution system as part of an addition or renovation;duct must be R-6 installed per Sec.503.2.7.2. <br /> (5)For all conventional units wilh capacities greater than 30,000 Blu/hr For othe�lypes o(equipment,see Tables 503.2.3(1-8). <br /> Exception:The prohibition on eleclric resistance heat does not apply to additions,renovations and new heating systems installed in existing buildings. <br /> (6)For other eleclric storage volumes,minimum EF=0.97-(0.00132 x volume). <br /> (7)For olher natural gas storage volumes,minimum EF=0.67-(0.0019 x volumej. , <br /> TABLE 402B MAN�ATORY REOUIREMENTS <br />� COMPONENTS SECTION REOUIREMENTS CHECK <br /> To be caulked,gasketed,weatherslripped or olherwise sealed.Recessed Iighfing IGrated as meeling ASTM E <br /> I Air leakage ,402.4 283.Windows and doors=0.30 cfmisq.tt.Testing or visual inspeclion required.Fireplaces:gasketed doors 8 <br /> outdoorcombustionair. � <br /> Ceilings/knee walls 4052.1 R-19 space permitting. <br /> Programmable lhermoslat 403.1 1 Where(orced-air furnace Is primary system,programmable thermostat is required. <br /> Air distribution system 4032 Ducts in attics or on rools insulated to R-8;other ducls R-6.Ducts tesled to Q,=0.03 by a Class 1 BERS raler. <br /> Heat Irap required lor veAical pipe risers.Comply with efficlencies in Table 403.4.3.2.Provide switch or clearly <br /> Waler heaters 403.4 marked circuit breaker(electric)or shWott (gas).Circulating system pipes insulaled lo=R-2+accessible manual <br /> OFF switch. <br /> i Spas and heated pools musl have vapor-retardant Govers or a liquld cover or olher means proven to reduce heat <br /> Swimming pool 8 spas 403.9 � lass except If 70%of heat(rom sile-recovered energy.Off/timer switch required.Gas heaters minimum thermal <br /> " efficien =78% 82%afler 4/16/13.Heat um ool heaters minimum COP=4.0. <br /> Sizing calculation per(ortned&attached.Minimum efficiencies per Tables 5032.3.Equipment efficiency verification <br /> Coolingfieating equipment 403.6 required.Special occasion cooling or heating capaciry requlres separate system or variable capacity system. <br /> Eleclric heal>10kW must be divided into iwo or more s1a es. <br /> Lighling equipment 404.1 ' At leasl 50%of pertnanently installed lighting fixtures shall be high-eKcacy lamps. <br /> 2010 FLORI�A BUILDING CODE—ENERGY CONSERVATION C.5 <br />