My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
15-16701
Zephyrhills
>
Building Department
>
Permits
>
2015
>
15-16701
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2017 11:51:12 AM
Creation date
2/21/2017 11:50:09 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
15-16701
Building Department - Name
LUCKEY,SHERMAN & ALISE
Address
39119 PARK DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, _. <br /> �v�� �� . <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Luckey Residence Builder Name: y-��� �yQ�' ���G <br /> SVeet 39119 PARK DR Pertnit Ofiice: (,'��� ur 2 ePhYr�`'� <br /> Ciry,Slate,Z'ip: ZEPHYRHILLS,FL,33542 Permit Number. /b � <br /> Owner: All State Homes Jurisdiction: �f((o d a <br /> Desig�Localion: FL,Tampa <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1424.0 sqfl.) Insulalion Area <br /> 2. Sin ie famil or multi le fami� Sin le-famii a.Concrete Block-Int Insul,Exterior R=4.1 1240.00 ft2 <br /> 9 Y P Y 9 Y b.Frame-Wood,Adjacent R=11.0 184.00 ft= <br /> 3. Number of units,if mulGple family 1 c.N/A R= ftz <br /> 4 Number of Bedrooms 3 d.N/A R- ft= <br /> 10.Ceiling Types (1885.0 sqft.) Insulation Area <br /> 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 '1747.00 ft� <br /> 6. Conditioned Boor area above grade(ftZ) 1739 b.Knee Wall(Vented) R=19.0 138.00 ftZ <br /> c.N/A R= ftz <br /> Conditioned floor area below grade(fl') � 11.Ducts R K' <br /> 7_ Windows(203.6 sqft.) Description Area a.Sup:Atlic,Ret:AtUc,AH:Entire Space 6 268 <br /> a. U-Factor. Dbl,U=0.63 95.14 ft' � <br /> SHGC: SHGC=0.33 <br /> b. U-Factor. Dbl,U=0.56 46.41 ft' 12 Cooling systems kBlu/hr Efficiency <br /> SHGC: SHGC=0.37 a.Central Unit 28.6 SEER:14.00 <br /> c. U-Factor. Dbl,U=0.45 4020 ftz <br /> SHGC: SHGC=0.43 13_Heating systems kBtulttr Efficiency <br /> d. U-Factor. olher(see details) 21.90 ft' a.Electric Heat Pump 28.6 HSPF:8.20 <br /> SHGC: olher(see details) <br /> Area Weighted Average Overhang Depth: 4.767 ft. <br /> Area Weighted Average SHGC: 0.360 14.Hol water systems <br /> a.Electric Cap:40 gallons <br /> 8. FloorTypes (1739.0 sqft.) Insulatio� Area EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1739.00 ftZ b. Conserva6on features <br /> b.N/A R= hZ None <br /> c.N/A R= ft' 15.Credits None <br /> Glass/FloorArea: 0.117 Total Proposed Modified Loads: 51.97 pASS <br /> Total Baseline Loads: 53.84 <br /> I hereby certify that the plans and specifications covered by Review of the plans and 4'tKE STAT <br /> this calculation are in complian with jhe Florida Energy specifications covered by this ��� "; _�0,� <br /> Code. � calculation indicates compliance y�v„; ==�°�� <br /> � /� with the Florida Energy Code. � n,ir,�°�-..r:;a�;:��•��� 0 <br /> PREPARED BY: Before construction is completed � --=;- � <br /> DATE_ this building will be inspected for � -S"�'�" . a <br /> compliance with Section 553.908 . � C , ,. <br /> I hereby certify that is building,as designe is in compliance Florida Statutes. 1�, �y�C <br /> with the Florida Energy de. � C�D WE� <br /> OWNER/AGENT: BUILDING OFFIC� L: <br /> DATE: DATE: 0"a ^ �� <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. � <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.000 Qn for whole house. <br /> 9/14/2015 4:59 PM EnergyGaugeB USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.