My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
15-16701
Zephyrhills
>
Building Department
>
Permits
>
2015
>
15-16701
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2017 11:51:12 AM
Creation date
2/21/2017 11:50:09 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
15-16701
Building Department - Name
LUCKEY,SHERMAN & ALISE
Address
39119 PARK DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Rhvac-Residential&Light Commercial HVAC Loads . � Elite Software Development,lnc. <br /> Nuccio Heatinq and Air : __ , _ .._ . , , �: _ . , _ �. _ :: , . Luckey Residence <br /> Tampa.FL 33625- �"+�� Page 2 <br /> Project Report _ _ <br /> Gene�af Project Information:> :. �. ' • � ,�„__.,�,� � <br /> Project Title: Luckey Residence <br />' Project Date: Tuesday, November 11,2014 <br /> Client Name: All State Homes <br /> Design Data "� � � ` �� '� � <br /> . _ � � __:_.,..,,_ �-- — - . <br /> Reference City: Tampa AP, Florida <br /> Building Orientation: Front door faces South <br /> Daily Temperature Range: Medium <br /> Latitude: 28 Degrees <br /> Elevation: 19 ft. <br /> Altitude Factor: 0.999 <br /> Outdoor Outdoor Outdoor Indoor Indoor Grains <br /> D�-y Bulb Wet Bulb $el.Hup� $el.Hup7 �Bulb Difference <br /> Winter: 40 37.52 n/a n/a 70 n/a <br /> Summer: 91 77 54% 50% 75 53 <br /> Check•Fi ures ' ' � • � ' � `� <br /> Total Building Supply CFM: 932 CFM Per Square ft.: 0.536 <br /> Square ft. of Room Area: 1,739 Square ft. Per Ton: 814 <br /> Volume(ft3)of Cond. Space: 15,568 � <br /> .Bu'ildin -Loads` � � � � - � <br /> Total Heating Required Including Ventilation Air: 24,144 Btuh 24.144 MBH <br /> Total Sensible Gain: 20,482 Btuh 80 % <br /> Total Latent Gain: 5,169 Btuh 20 % <br /> Total Cooling Required Including Ventilation Air: 25,651 Btuh 2.14 Tons(Based On Sensible+ Latent) <br /> Notes . � .. � , _ ., - , , . . - <br /> � .�.__._.....____� - r.,.�_.�. _..�_.�...�. <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. <br /> i <br /> \\PLOTTER_RICOH\wrightapps ...WLL STATE LUCKEY 9,15.rh9 Wednesday, September 23,2015,3:33 PM <br />
The URL can be used to link to this page
Your browser does not support the video tag.