�, �'� ... I
<br /> "�' � ��d @I� @ 8�f ����
<br /> APPENDIX 1:ATTACHMENT REQUtREMEPlTS POR WIND UPLIFT RESIS7ANCE - � � � � " � � -
<br /> Table Deck Application Type Description Page
<br /> 1A-1 Wood New or Reroof(Tear-Off) A-2 Mech.Attached AnchorSheet,Bonded Insulatlon,Bonded Roof Cover 3
<br /> lA-2 Wood New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 3
<br /> 18 Wood New,Reroof(Tear-Offl or Recover C Mech.Attached Insufation,Bonded Roof Cover 4
<br /> 1C Wood New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulatlon,Mech.Attached Base Sheet,B n over 4
<br /> 1D-1 Wood New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached 8ase Sheet(nails),B 4
<br /> iD-2 Wood New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet(scr p oof Cover 5
<br /> 1E Wood New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 5
<br /> 2A Steel or Conc. - New,Reroof(Tear-Off)or Recover C Mech.Attached Insulatlon,Bonded 6
<br /> 2B Steel or Conc. New,Reroof(Tear-Of�or Recover D Prelim.Attached Insulation,M e ed Roof Cover 6
<br /> 3A-1 Concrete New or Reroof(Tear-Off) A-1 Bonded Insulatlon,Bond 7-8
<br /> 3A-2 Concrete New or Reroof(Tear-Off) A-1 Bonded Temporary Ro . d Roof Cover 9
<br /> 3B Concrete New or Reroof(Tear-Offl F Non-Insulated,Bonded 9
<br /> 4A LWIC New or Reroof(Tear-Off► A-1 Bonded Insulatlon,Bonde � 10
<br /> 4B ` LWIC � New or Reroof(Tear-Offl A-2 Mech.Attached Anchor She , nded Insulation,Bonded Roof Cover il
<br /> 4C LWIC � New or Reroof(Tear-Of� E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cov 11
<br /> 5A CWF New or Reroof(Tear-Off) A-i Bonded Insulation,Bonded Roof Cover 12
<br /> SB CWF New,Reroof(Tear-Offl or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulatlorti R r,�0 12
<br /> 6A Gypsum New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover j 13
<br /> 7A Various Recover A-1 Bonded Insutatlon,Bonded Roof Cover 14
<br /> The followlaR notes aoplv to the svstems outlined herein: ��
<br /> 1. The roof systerri evaluation hereln pertains to above-deck roof components. Roof decks an'd structurel members shall be in accardance with FBC requfrements to the satisfaction of the AHJ. Load resistance of the
<br /> roof deck shall be documented through proper codified and/or FBC Approval documentation.
<br /> 2. Insulation/base sheet fasteners shall be of sufficlent length for the following deck engagement:
<br /> 00 • Mlnimum 0.75-Inch penetration.
<br /> ➢Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck.
<br /> ➢Concrete: Mlnimum 1-inch embedment Into pilot hole In accordance with fastener manufacturer's publlshed fnstallation instructions.
<br /> 3. Unless otherwise noted,insulation may be any one layer or combination of polyisocyanurate,polystyrene,wood fiberboard,periite or gypsum-based roof board that meets the qA�equirements of F.A.C.Rule 61G20-
<br /> 3 and is documented as meeting FBC 1505.1 and,for foam plastic,F8C Chapter 26,when installed with the roof cover.
<br /> 4. Minimum 200 psi,minimum 2-inch thick Iightweight Insulating concrete may be substituied for rigid Insulatlon board for System Type D(mechanically attached base sheet,bonded roof cover),whereby the base
<br /> sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck Iistings. Roof decks and
<br /> strudurel members shall be in accordance with FBC requirements to the satisfactfon of the AHJ. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
<br /> 5. Unless otherwlse noted,insulatlon adhesive appllcatlon rates are as follows. Ribbon or bead wldth is at the time of application;the ribbons/beads shall expand as noted in the manufacturers published fnstructions.
<br /> ➢ HA(HA): Full coverage at 25-30 Ibs/square.
<br /> ➢ Dow Insta-Stik Rooflng Adheslve(D-IS): Continuous 0.75 to 1-lnch wide ribbons,l2-Inch o.c.
<br /> ➢ Millennium One Step Foamable Adhesive(M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons,l2-inch o.c.
<br /> ➢ OMG OlyBond 500(OB500): Continuous 0.75 to i-inch wide ribbons, 12-Inch o.c. �PaceCart or SpotShot). Note: OlyBond Green may 6e used where OfyBond 500 Is
<br /> referenced.
<br /> D OlyBond Classic(OB Classic): Full coverage at 1 gal/square.
<br /> ➢ 3M CR-20: Continuous 2.53.5-inch wide ribbons,l2-inch o.c.
<br /> Exterior Research and Oesign,LLC,d/b/a Trinity�ERD Evaluation Report M10000.03.�8-R4 for FL30497-R4
<br /> Certificate of Authorization#9503 Revision 4:04/22/2015
<br /> Prepared by: Robert Nieminen,PE-59166 .� AppendUc 1,Page 1 of 14