Laserfiche WebLink
.% ' � " � <br /> FORM R405-2014 <br /> WALLS <br /> ,/ Adjacent Cavity Width Height Sheathing Framing Solar Below <br /> -Y#�-Om�_Tn-aAIaILTypP Spa� R-valu�Ft �� F�J� Area--.R-Value_.�F�action-Absor__�radeJo_ <br /> 1 S=>SW Exterior Concrete Block-Int Insul Main 15 18 8 S 149.3 ft' 0 0 0.75 0 <br /> 2 E=>SE Exterior Concrete Block-Int Insul Main 15 6 8 48.0 ftZ 0 0.75 0 <br /> 3 W=>IVW Exterior Concrete Block-Int Insui Main 15 56 8 448.0 ft� 0 0 0.75 0 <br /> 4 N=>NE Exterior Concrete Block-Int Insul Main 15 27 8 216.0 ftZ 0 0 0.75 0 <br /> 5 E=>SE Exterior Concrete Blodc-Int Insul Main 15 10 8 8 85.3 ft� 0 0 0.75 0 ' <br /> _ 6 P1=>NE Exterior Concrete Block-lnt Insul Main 15 11 8 88.0 ftz 0 0.75 0 <br /> 7 E=>SE Exterior Concrete Block-lnt Insul Main � 15 52 8 8 421.3 ftZ U 0.75 0 � <br /> _8 S=>SW Garage Frame-Wood Main 11 18 8 144.0 ft 0.23 0.75 0 � <br /> _9 W=>NW Garage Frame-Wood Main 11 5 4 8 42.7 ftz 0_23 0.75 0 ' <br /> _10 E=>SE Garage Frame-Wood Main 13 9 8 72.0 ftZ 0.23 0.75 0 <br /> DOORS • ! <br /> # Omt Door Type Space Storms U-Value Width Height Area � <br /> _ �^ Ft In Ft In i <br /> 1 S=>5W Insulated Main None .46 3 6 8 20 fN <br /> 2 S=>SW Insulated Main None .46 2 8 6 S 17.8 ftZ <br /> WiNDOWS <br /> Orientation shown is the entered orientation(_>)chan ed to Worst Case. <br /> � Wall Qverhang <br /> # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening <br /> 1 S=>SW 1 Metal Low-E Single Yes 0.56 0.32 30.0 ft� 'I ft 0 in 1 ft 0 in Drapes/blinds None <br /> � 2 W=>NW 3 Metal Low-E Single Yes 0.59 0.32 14.8 ft' 1 ft 0 in 1 ft 0 in Drapes/blinds None <br /> 3 E=>SE 7 Metal Low-E Single Yes 0.59 0.32 38.1 f� 1 ft 0 in 1 ft 0 in Drapes/blinds None <br /> 4 E=>SE 7 Metal Low-E Single Yes 0.59 0.32 5.3 ft 1 ft 0 in 1 ft 0 in Drapes/blinds None <br /> 5 N=>NE 4 Metal Low-E Single Yes 0.56 0.32 40.0 ft2 11 ft 0 in 1 ft 0 in Drapes/blinds None <br /> 6 N=>NE 6 Metal Low-E Single Yes 0.59 0.32 45.0 ftZ 1 ft 0 in 1 ft 0 in Drapes/blinds None <br /> 7 N=>NE 6 Metal Low-E Single Yes 0.59 0.32 6.9 ftz 1 ft 0 in 1 ft 0 in Drapes/blinds None <br /> GARAGE <br /> # FloorArea Ceiling Area Exposed Wall Perimeter Avg.Wall Height 6cposed Watl Insulation <br /> 1 378 ft2 380 ftz 32.4 ft 8 ft 75 <br /> INFILTRATION � <br /> # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 <br /> 1 Wholehouse Proposed ACH(50) _000254 1143.3 62_77 118.04 .1906 5 <br /> I <br /> 8/4/2015 4:54 PM � EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 <br />