Laserfiche WebLink
- 1 <br /> . .� Wr��h$��.�m Pro ect Summar Job: R1195486 <br /> .� y Date: 11-17-1 S <br /> Entire Hous� BY� ��� <br /> Bahr's Propane Gas �AC Inc <br /> 4441 Alten Rd,Zephyrhills,FL33St1 Phone;813-782-50'13 <br /> � i ` # ! <br /> For: Butterteld Quadplex Unit 6-1 �I <br /> 4408 Caurt St, Zephyrhi(Is, FL 33542 <br /> Nates: Load Calculation was abtamed fram an on-site inspection. <br /> i - • s • <br /> Weather: Lakeland Co(S), FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Oufside db 41 °F Outside db 89 °F <br /> Inside db 70 °F Inside db 75 °F <br /> Design TD 29 °F Design TD 96 °F <br /> Daily range M <br /> Relative humidity 50 % <br /> Moisture difference Q7 gr/Ib <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 15350 Btuh Structure 13615 B#uh <br /> Ducts 3379 Btuh Ducts 5710 Btuh <br /> Gentral vent(0 cfm) 0 Btuh Centra!vent(Q cfm) 0 Btuh <br /> Humidi�cation 0 Btuh Blower 1416 Btuh <br /> Piping 0 Btuh <br /> Equipment load 18729 Btuh tJse manufacturer's data y <br /> Ratelswing mu(tiplier 1,00 <br /> 111filtra�tlon Equipment sensible load 20741 Btuh <br /> Mett,od Simplified Latent Gooling Equipment Load Sizing <br /> Construction quality Average <br /> Fireplaces 0 Str�cture 22Q0 Btuh <br /> Ducts 1274 Btuh <br /> Heating Cooling Central vent (0 cfm) 0 Btuh <br /> Area{ftZ 1435 1435 Equipment latsnt load 3474 Btuh <br /> Volume ft3} �1480 11480 <br /> Air changes/hour 0.45 0.23 Equipment total Ioad 24216 Btuh <br /> Equiv.AVF (cfm) 86 44 Req.total capacity at 0.75 SHR 2.3 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Make Ternpstar or Eqv. <br /> Trade Trade TEMPSTAR <br /> Model Cond N4A330A(G)KC* <br /> AHRI ref Coil FXM4X30'"`A* <br /> AHRI ref 3692289 <br /> Efficisncy 1 QO EFF' Efficiency 11.5 EER, 14 SEER <br /> Heating input 8.0 kW Sensible caoling 20$50 Btuh <br /> Heating output 27297 Btuh Latent cooling 6950 Btuh <br /> Temperature rise 96 °F "Cotal coaling 27800 Btuh <br /> Actual air flaw 261 cfm Actual air ftaw 927 cfm <br /> Air flow factor 0.014 cfm/Btuh Air flow factor O.G48 cfm/Btuh <br /> Static pressure 0.50 in H20 8tatic pressure 0.50 in H20 <br /> Space therntostat Load sensible heat ratio 0.86 <br /> Galculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> 2�15-Nov-i9 13:57:13 <br /> „ wrightsoft° Right-SuiteQ+3 Universa)2015 45.0.21 RSU07440 Page 1 <br /> ��...Ie1R1115466-Butterfield1R1115486 Unit E1.rup Calc=MJe Building Front faces: N <br />