My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
15-16748
Zephyrhills
>
Building Department
>
Permits
>
2015
>
15-16748
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2017 1:32:29 PM
Creation date
2/21/2017 1:32:28 PM
Metadata
Fields
Template:
Building Department
Company Name
WALNUT GROVE TOWNHOMES
Building Department - Doc Type
Permit
Permit #
15-16748
Building Department - Name
BUTTERFIELD MOBILE HOME SERVICE
Address
37758 PRAIRIE ROSE LP LOT 56
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r � <br /> Y� <br /> ' FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: R1115486 Unit 6-1 � � � Builder Name: �Q��l,�/,CG� �� <br /> Street: 44�B8-EVQR'st 377�� ��R,1/i p 52� Permit Office: ity of Z��phyrhills <br /> City,State,Zip: Zephyrhills,FL,33542 �-T S,� Permit Number: f�'7 � <br /> Owner: Buttertield Quadplex L�+�it�6-�- Jurisdiction: 611600 �� <br /> Design Location: FL,Tampa <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1400.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=5.0 1213.30 ft' <br /> b.Frame-Wood,Adjacent R=13.0 186.67 ft' <br /> 3. Number of units,if multiple family 1 c.N/A R= ft' <br /> 4. Number of Bedrooms 3 d.N/A R= ft' <br /> 5. Is this a worst case? No 10.Ceiling Types (1435.0 sqft.) Insulation Area Z <br /> a.Under Attic(Vented) R=30.0 1435.00 ft <br /> 6. Conditioned floor area above grade(ft� 1435 b.N/A R= ft' <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ftZ <br /> 11.Ducts R ftZ <br /> 7. Windows(137.0 sqft.) Description Area a.Sup:Attic, Ret:Attic,AH:ah 6 225 <br /> a. U-Factor: Dbl,U=0:54 137.00 ft' <br /> SHGC: SHGC=0.30 <br /> b. U-Factor: N/A ft' '12-Cooling systems kBtu/hr Efficiency <br /> SHGC: a.Central Unit 27.8 SEER:14.00 <br /> c. U-Factor: N/A ftZ <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft' a.Electric Strip Heat 27.3 COP:1.00 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.672 ft. j <br /> Area Weighted Average SHGC: 0.300 14.Hot water systems <br /> 8. Floor Types (1435.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF:0.970 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1435.00 ft' b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ft' 15.Credits CF <br /> Glass/Floor Area: 0.095 Total Proposed Modified Loads: 46.91 pASS <br /> Total Baseline Loads: 46.78 <br /> I hereby certify that the plans and specifications covered by Review of the plans and D�T'i�S?'�.8 <br /> this calculation are in compliance with the Florida Energy specifications covered by this „�+ "' = .- � p� <br /> Code. calculation indicates compliance ��`�,,,�''' '��',,o�. r, <br /> ��/ with the Florida Energy Code. � rr�,�•�;-'�=:�".�;,���,� � <br /> :�= <br /> PREPARED BY: Before construction is completed � - " _ <br /> 11-19-15 a _. ���,_ rt <br /> DATE: this building will be inspected for � - ���,Y, " �, , <br />' compliance with Section 553.908 * �? '� x � <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. ;� ��, <br /> with the Florida Energy Code. , ; � �flD{+�'1`�� <br /> OWNER/AGENT: BUILDING OFFIC AL: <br /> DATE: DATE: "�t�-�rr <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifes as <br /> certified factory�ealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br />, 11/19/2015 1:54 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software � Page 1 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.