My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
15-16798
Zephyrhills
>
Building Department
>
Permits
>
2015
>
15-16798
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2017 9:43:55 AM
Creation date
2/22/2017 9:41:25 AM
Metadata
Fields
Template:
Building Department
Company Name
ALL CRAFT MARINE HOLDINGS LLC
Building Department - Doc Type
Permit
Permit #
15-16798
Building Department - Name
ALL CRAFT MARINE HOLDINGS LLC
Address
40047 COUNTY ROAD 54
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Architects and Engineers Specifications � <br /> � �------ --- --__--- --- -- ------ - --_ __ _. : <br /> The notification appliances shall be Wheelock�ExcederT"^Series HS Audible Strobe appliances, Series ST Visual Strobe appliances <br /> and Series HN Audible appliances or approved equals.The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency <br /> Devices for the Hearing-Impaired)for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard <br /> 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B.All inputs shall be compatible with <br /> standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel(FACP)with the ability to operate from 8 to 33 VDC. <br /> Indoor wall models shall incorporate voltage test points for easy voltage inspection. <br /> The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated <br /> Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan�lens.The Series shall be of low current design. <br /> Where Multi-Candela appliances are specified,the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30,75,95, 110, <br /> 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting <br /> the candela shall be tamper resistant.The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with <br /> 75 candela on-axis is required (e.g.ADA compliance). Appliances with candela settings shall show the candela selection in a visible <br /> location at all times when installed. <br /> The audible shall have a minimum of three(3)field selectable settings for dBA levels and shall have a choice of continuous or temporal <br /> (Code 3) audible outputs. <br /> The Series HS Audible Strobe,ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow <br /> mounting to a single-gang, double-gang,4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire <br /> appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to <br /> attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of <br />' an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel(FACP). The mounting base shall be the same <br /> base among all horn, strobe, horn strobe,wall and ceiling models. All notification appliances shall be backwards compatible. <br /> The Series HS and ST wall models shall have a low profile measuring 5.24"H x 4.58"W x 2.19"D. Series HN wall shall measure 5.24" <br /> H x 4.58"W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68"x 2.63" D. Series <br /> HNC ceiling shall have a diameter of 6.68"x 1.50"D. <br /> When synchronization is required,the appliance shall be compatible with WheelockOO's SM, DSM Sync Modules,WheelockOO Power <br /> Supplies or other manufacturer's panels with built-in WheelockOO Patented Sync Protocol.The strobes shall not drift out of synchronization <br /> at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still <br /> maintain (1)flash per second over its Regulated Voltage Range.The appliance shall also be designed so that the audible signal may <br /> be silenced while maintaining strobe activation when used with WheelockOO synchronization protocol. <br /> — 971 UL Standard 464 California State Fire Marshal (CSFM), ULC <br /> Wall Appliances UL Standard 1 <br /> Ceiling Appliances—UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC <br /> ������ - <br /> WE ENCOURAGE AND SUPPORT NICET CERTIFICATION <br /> 3 YEAR WARRANTY <br /> Exceder- Spec Sheet 11/09 <br /> . �� :. . � <br /> . . '� ,� . � <br /> :��•. �� <br /> � � .� / <br /> _ , <br />�, cooPerNotifcationisWhe210Ck° MEDC SAFEPATH� WAVE� a COOPERNotification <br /> 0 <br /> � � <br />� <br />
The URL can be used to link to this page
Your browser does not support the video tag.