Laserfiche WebLink
:c <br /> FORM R405-2014 <br />� <br /> FLORID�4 EIVERC�Y EFFI�EENCY CODE FOR BUILDING COIVSTRUCTIOId <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project-Al�me:, _Olean r,ll Mod I�. � Builder Name. Highland�Iomes r���`s <br /> St�eet: � ��� ��:-L �. , � �n. Permit Office: (�'�Q)� Z��� � <br /> City,Stat` e,7 p: ,�C, � � Permit Number IG�3d3 <br /> � Owner• ���� �,I Jurisdiction: //(�� <br /> `� � <br /> Design Location. FL,Lakeland <br />' - 1 New construction or existing New(From Plans) 9. Wall Types(1392.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=15.0 1138.00 ft' <br /> b.Frame-Wood,Adjacent R=11.0 256.00 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ftZ <br /> 4 Number of Bedrooms 3 d.N/A R= ftZ <br /> 10.Ceiling Types (1485.0 sqft.) Insulation Area <br /> 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1485.00 ft' <br /> 6. Conditioned floor area above grade(ftz) 1485 b.N/A R= ft' <br /> Conditioned floor area below grade(ft2) 0 c. N/A R= ft2 � <br /> 11.Ducts R ft' I <br /> 7 Windows(116.0 sqft.) Description Area a.Sup:Attic,Ret:Garage,AH:Garage 6 295.2 i <br /> a. U-Factor: Dbl,U=0.59 46.00 ft2 <br /> SHGC: SHGC=0.32 <br /> b. U-Factor. Dbl,U=0.56 40.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.4 SEER:14.00 <br /> c. U-Factor Dbl,U=0.59 30.00 ft' <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor• N/A ftZ a.Electric Heat Pump 34 4 HSPF:8.20 <br /> SHGC: <br /> . Area Weighted Average Overhang Depth: 2.000 ft. <br /> Area Weighted Average SHGC• 0.310 14.Hot water systems <br /> 8. FloorTypes (1485.0 sqft.) Insulation Area a.Electric Cap:40gallons <br /> EF:0.920 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1485 00 ft2 b. Conservation features , <br /> b.N!A R= ft2 None ' <br /> c.N/A R= ft� �5.Credits Pstat <br /> Glass/Floor Area: 0.078 <br /> Total Proposed Modified Loads. 42.50 pASS <br /> Total Baseline Loads: 43.77 <br /> I hereby certify that the plans and specifications covered by Review of the plans and 0��HE S�,qT <br /> this calculation are in compliance with the Florida Energy specifications covered by this ,y ,��,,�' _;;�0�, <br /> Code, calculation indicates compliance ���,,,,% ,,j-_;;'�.�`�\ .t� <br /> PAYNE AiR CONDITIONING ,�,�i t h t he F lori da Energy Co de. � �r,r„��,;.:::_._�.�•���a,,,, o <br /> � >� ,�� <br /> PREPARED BY: �C1,�], .],O� --- Before construction is completed • r� �-�'��� t�.. <br /> DATE: _ .� _ � � this building will be inspected for � -- ��}'� - 1i``� � <br /> , 1 4i�!F.-r <br /> compliance with Section 553.908 * --- � � <br /> I hereby certify that this building, as designed,is in compliance Florida Statutes. 1,� � y�, <br /> with the Florida Energy o e.� • � C�b{�'�� <br /> OWNER/AGENT:_ _ _�� 1 I ��.I_�V ►� _- BUILDING F IA�.: �,��� ___ _ _ _ <br /> DATE: -- � � -I--, DATE: --I��'(`J- - <br /> - Compliance requires cerfification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 7/23/2015 12:09 PM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 5 <br />