:c
<br /> FORM R405-2014
<br />�
<br /> FLORID�4 EIVERC�Y EFFI�EENCY CODE FOR BUILDING COIVSTRUCTIOId
<br /> Florida Department of Business and Professional Regulation - Residential Performance Method
<br /> Project-Al�me:, _Olean r,ll Mod I�. � Builder Name. Highland�Iomes r���`s
<br /> St�eet: � ��� ��:-L �. , � �n. Permit Office: (�'�Q)� Z��� �
<br /> City,Stat` e,7 p: ,�C, � � Permit Number IG�3d3
<br /> � Owner• ���� �,I Jurisdiction: //(��
<br /> `� �
<br /> Design Location. FL,Lakeland
<br />' - 1 New construction or existing New(From Plans) 9. Wall Types(1392.0 sqft.) Insulation Area
<br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=15.0 1138.00 ft'
<br /> b.Frame-Wood,Adjacent R=11.0 256.00 ft2
<br /> 3. Number of units,if multiple family 1 c.N/A R= ftZ
<br /> 4 Number of Bedrooms 3 d.N/A R= ftZ
<br /> 10.Ceiling Types (1485.0 sqft.) Insulation Area
<br /> 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1485.00 ft'
<br /> 6. Conditioned floor area above grade(ftz) 1485 b.N/A R= ft'
<br /> Conditioned floor area below grade(ft2) 0 c. N/A R= ft2 �
<br /> 11.Ducts R ft' I
<br /> 7 Windows(116.0 sqft.) Description Area a.Sup:Attic,Ret:Garage,AH:Garage 6 295.2 i
<br /> a. U-Factor: Dbl,U=0.59 46.00 ft2
<br /> SHGC: SHGC=0.32
<br /> b. U-Factor. Dbl,U=0.56 40.00 ft2 12.Cooling systems kBtu/hr Efficiency
<br /> SHGC: SHGC=0.32 a.Central Unit 34.4 SEER:14.00
<br /> c. U-Factor Dbl,U=0.59 30.00 ft'
<br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency
<br /> d. U-Factor• N/A ftZ a.Electric Heat Pump 34 4 HSPF:8.20
<br /> SHGC:
<br /> . Area Weighted Average Overhang Depth: 2.000 ft.
<br /> Area Weighted Average SHGC• 0.310 14.Hot water systems
<br /> 8. FloorTypes (1485.0 sqft.) Insulation Area a.Electric Cap:40gallons
<br /> EF:0.920
<br /> a.Slab-On-Grade Edge Insulation R=0.0 1485 00 ft2 b. Conservation features ,
<br /> b.N!A R= ft2 None '
<br /> c.N/A R= ft� �5.Credits Pstat
<br /> Glass/Floor Area: 0.078
<br /> Total Proposed Modified Loads. 42.50 pASS
<br /> Total Baseline Loads: 43.77
<br /> I hereby certify that the plans and specifications covered by Review of the plans and 0��HE S�,qT
<br /> this calculation are in compliance with the Florida Energy specifications covered by this ,y ,��,,�' _;;�0�,
<br /> Code, calculation indicates compliance ���,,,,% ,,j-_;;'�.�`�\ .t�
<br /> PAYNE AiR CONDITIONING ,�,�i t h t he F lori da Energy Co de. � �r,r„��,;.:::_._�.�•���a,,,, o
<br /> � >� ,��
<br /> PREPARED BY: �C1,�], .],O� --- Before construction is completed • r� �-�'��� t�..
<br /> DATE: _ .� _ � � this building will be inspected for � -- ��}'� - 1i``� �
<br /> , 1 4i�!F.-r
<br /> compliance with Section 553.908 * --- � �
<br /> I hereby certify that this building, as designed,is in compliance Florida Statutes. 1,� � y�,
<br /> with the Florida Energy o e.� • � C�b{�'��
<br /> OWNER/AGENT:_ _ _�� 1 I ��.I_�V ►� _- BUILDING F IA�.: �,��� ___ _ _ _
<br /> DATE: -- � � -I--, DATE: --I��'(`J- -
<br /> - Compliance requires cerfification by the air handler unit manufacturer that the air handler enclosure qualifies as
<br /> certified factory-sealed in accordance with R403.2.2.1.
<br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
<br /> test report in accordance with R402.4.1.2.
<br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
<br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house.
<br /> 7/23/2015 12:09 PM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 5
<br />
|