Laserfiche WebLink
; <br /> +• r <br /> � <br /> F�RM R405-2014 <br /> FLORIDA ECVEF�GY EFFICeEfVCY CODE FOR �UILDIN+C COfVS1'RUCTI�N <br /> Florida Department of Business and Professional Regulation - Residential Per#ormance Method <br /> Project ame: �ander II ode Builder Name. Hi hland Ho�s r���r� <br /> Street:iit"�`YI��(l �" � � . Permit Office:C! 0� �� E <br /> City,StF ip. �F'L, � p ` J Permit Number j��( <br /> Owner• ' '"� ��� l/� l Jurisdiction: <br /> � � ��� <br /> Design Location: FL,Lakeland <br /> 1 New construction or existing New(From Plans) 9. Wall Types(1392.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=15.0 1136.00 ftz <br /> b Frame-Wood,Adjacent R=11.0 256.00 ftZ <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4 Number of Bedrooms 3 d.N/A R= ft2 <br /> 5. Is this a worst case? No 10 Ceiling Types (1485.0 sqft.} Insulation Area Z <br /> a.Under Attic(Vented) R=30.0 1485.00 ft <br /> 6. Conditioned floor area above grade(ftz) 1485 b.NtA R= ft2 <br /> Conditioned floor area below grade(ftZ) 0 c. N/A R= ftz <br /> 11 Ducts R ft' <br /> 7. Windows(116.0 sqft.) Description Area a.Sup.Attic,Ret:Garage,AH:Garage 6 295.2 <br /> a. U-Factor Dbl,U=0.59 46.00 ft2 <br /> SHGC• SHGC=0.32 � <br /> b. U-Factor: Dbl,U=0.56 40.00 ftz 12.Cooling systems kBtuJhr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.4 SEER:14.00 <br /> c. U-Factor Dbl,U=0.59 30.00 ftz <br /> SHGC: SHGC=0.28 13.Heating sysfems kBtu/hr Efficiency <br /> d. U-Factor• N/A ft2 a.Electric Heat Pump 34.4 HSPF:8.20 <br /> SHGC: � <br /> Area Weighted Average Overhang Depth: 2.000 ft. <br /> Area Weighfed Average SHGC• 0.310 14 Hot water systems <br /> 8. Floor Types (1485.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF:0.920 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1485.00 ft2 b. Conservation features <br /> b.N!A R= ftZ None � <br /> c.N/A R= ft� 15.Credits Pstat <br /> Glass/FloorArea: 0.078 Total Proposed Modified Loads: 42.50 pASS <br /> Total Baseline Loads: 43.77 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ���HE S�^,qr� <br /> this calculation are in compliance with the Florida Energy specifications covered by this � , ,•' "= a . Or, <br /> Code. calculation indicates compliance �'`��.,,�;% '=���'��.�` �'� <br /> PAYNE AIR CONDITIONING With the Florida Energy Code. � .«,,,���,.::;:=ar�,��,;;,�o <br /> PREPARED BY: _._ .�. . _��1,$], -,,Q� - - Before construction is completed � c:3 �; �,i' � <br /> 7 �, `_`"�� -�_-s-- o <br /> DATE: _ /�.��� --- this building will be inspected for c� - �},li� � <br /> compliance with Section 553.908 * � � ' � <br /> I hereby certify that this building,as designed,is in compliance Florida Statutes. 1,�, �- �•S. <br /> with the Florida Energy e. ' � ��� C�b{�"Cg`� <br /> OWNER/AGENT:__- _ _ _ _ __ _ _-__ BUILDIN�j FF}�IAL:� _ __ � -___ <br /> DATE: -- - - - -- - - DATE: /�=7==�.�-- �_._. <br /> - - � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as , <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage � <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for wHole house. <br /> 7/23/2015 12:09 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />