Laserfiche WebLink
' 1 <br /> ' FORM R405-2014 <br /> � ENERGY PERFOR1111�4NCE LEVEL (EPL� <br /> �ISPL�►Y Ci4RD <br /> ESTIMATED ENERGY PERFORMANCE INDEX� = 97 <br /> The lower the EnergyPerformance Index, the more efficient the home. <br /> „ FL, <br /> 1. New construction or existing New(From Plans) 9 Wall Types Insulation Area <br /> 2. Single family or multiple family Singie-family a.Concrete Block-Int Insul, Exterior R=15.0 913E.00 ftZ <br /> b.Frame-Wood,Adjacent R=11.0 256.00 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 3 d.N/A R= ftZ <br /> I 5. Is this a worst case? No 10 Ceiling Types Insulation Area <br /> a.Under Attic(Vented) R=30.0 1485.00 ft2 <br /> 6. Conditioned tloor area(ft�) 1485 b.N/A R= ft2 <br /> 7 Windows""` Description Area c.N/A R= ftz <br /> a. U-Factor: Dbl,U=0.59 46.00 ft2 �1 Ducts R ft' <br /> a.Sup;Attic,ftet:Garage,AH:Garage 6 295.2 <br /> SHGC: SHGC=0.32 <br /> b. U-Factor� Dbl,U=0.56 40.00 ft2 <br /> SHGC: SHGC=0.32 12.Cooling systems kBtu/hr Efficiency <br /> c. U-Factor• Dbl,U=0,59 30.00 ft' a.Central Unit 34.4 SEER:14.00 <br /> SHGC: SHGC=0.28 <br /> d. U-Factor N/A ftZ 13.Heating systems kBtu/hr Efficiency <br /> SHGC: a.Electric Heat Pump 34 4 HSPF:8.20 <br /> Area Weighted Average Overhang Depth: 2.000 ft. <br /> Area Weighted Average SHGC• 0.310 <br /> 8. Floor Types Insulation Area 14.Hot water systems <br /> : a.Electric Cap:40 gallons <br /> a.Slab-On-Grade Edge Insulation R=0.0 1485.00 ft EF•0.92 <br /> b.N/A R= ft2 <br /> c.N/A R= ft= b. Conservation features <br /> None <br /> 15.Credits Pstat <br /> I certify that this home has complied with the Florida Energy Efficiency Code for Building �HEST <br /> Construction through the above energy saving features which will be installed (or exceeded) �,Q�,,. � �TG� <br /> in this home before final inspection. Otherwise, a new EPL Display Card will be completed �k3`;,,'%r •:=�',,l�, <br /> ��, r,�,,,�,�q`',�,,;�;;:;i�;.�;;�`�� p <br /> based on installed Cod compliant features. ���, :; ,,,,�,,,, <br /> � Q ' ����,, � , a`-'"�t}�;�-;����� <br /> BuilderSignature: t..C, �W 1 Y I Date; �,�_ �- �5 -- � ;Y�,� �� <br /> - - -- -- ��,�,-�-- -,-I - „ �' � � <br /> Address of New Hom . 3�� �p � y,�1��� City/FL Zip: -�� ���I� 1j, c,� <br /> `��d � <br /> ��� caD wL'i'�v <br /> *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient <br /> mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) <br /> 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For <br /> information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support <br /> staff. <br /> *'`Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. <br /> 7l23/2015 12:09 PM EnergyGauge�USA-FlaRes2014 -Section R405.4 1 Compliant Software Page 1 of 1 <br />