Laserfiche WebLink
' , FORMS <br /> TlaBLE 402A ' <br /> � BUILDING COMPONENT PERFORMANCE CRRERIA' INSTALLED VALUES: ' <br /> U-Factor<0.65 U-Factor= <br /> Windows(see Note 2): SHGC=0.30 SHGC= <br /> %ofCFA<=20% <br /> S li hts U-Factor<0.75 <br /> a of CFA= <br /> Doors:Exterior door U-Factor U-Factor<0.65 -Factor= <br /> Floors: Slab-on-grade No requirement -Value= <br /> Over unconditioned s aces see Note 3 R-13 <br /> Walls—Ext.and Adj.(see Note 3): <br /> Frame R-13 -Value= <br /> Mass (see Note 3) <br /> Interior of wall: R-7.8 -Value= <br /> Exterior of wall: R-6 -Value= <br /> Ceilings(see Notes 3&4) R=30 -Value= Test report <br /> Refiectance 025 eflectance= Attached7 <br /> Yes/No <br /> Air distribution system(see Note 4) <br /> Ductwork&air handling unit: Location: Test reporl <br /> Unconditioned space Not allowed Allached? <br /> Conditioned space Yes1No <br /> Duct R-value R-value z 6 R-Value= <br /> Air leakage�n �n 5 0.03 Q�_ <br /> Air conditionin s stems see Nole 5 SEER=13.0 SEER= <br /> Heating system <br /> Heat pump(see Nole�5) Cooling: SEER=13.0 SEER= <br /> Heating: HSPF=7.7 HSPF= <br /> Gas Furnace AFUE 78% AFUE= I <br /> Oil furnace AFUE 78% AFUE_ , <br /> Electric resistance:Not allowed(see Note 5) j <br /> Water heating system(storage type) I� <br /> Electric(see Note 6}: 40 gal:EF=0.92 Gallons= <br /> 50 gal:EF=0.90 EF= , <br /> I Gas fired(see Note 7): 40 gal:EF=0.59 Gallons= <br /> Other(describe): 50 gal:EF=0.58 EF= <br /> (1)Each component present in the As Proposed home must meet o ceed each of the applicable rformance criteria in orderto comply with this code using this method; <br /> otherwise Section 405 compliance must be used. <br /> (2)Windows and doors qualifying as glazed fenestration areas must complywith e maximum U-Factorand the maximum SHGC(solarHeat Gain Coefficient)criteria . <br /> and have a maximum total window area equal to or less ihan 20%of the conditioned floor area(CFA);otherwise Section 405 must be used for compliance. <br /> Exception: Additions of 600 square feet(56 mZ)or less may have a maximum glass to CFA of 50 percent. , <br /> (3)R-values are for insulation material only as applied in accordance with manufacturers'installation instructions.For mass walls,the"interior of wall"requirement musi be <br /> met except if at least 50%of the R-6 insulation required for the"exterior of wall"is installed exterior of,or integral to,the wail. <br /> (4)Ducts&AHU instalied substantially leak free per Section 403.2.2.1 Test by Class 1 BERS rater required. <br /> Exception:Ducts installed onto an existing air distribution system as part of an addition or renovation;duct must be R-6 installed per Sec.5032.7.2. <br /> (5)For all conventional units with capacities greater than 30,000 Btu/hr. For other types of equipment,see Tables 503.2.3(1-8). <br /> Exception:The prohibition on electric resistance heat does not apply to additions,renovations and new heating systems installed in existing buildings. <br /> (6)For other electric storage volumes,minimum EF=0.97-(0.00132 x volume). <br /> (7)For other naturai gas storage volumes,minimum EF=0.67-(0.0019 x volume). <br /> TABLE 4028 MANOATORY REQUIREMENTS <br />� COMPONENTS SECTION REQUIREMENTS CHECK <br />� To be caulked,gaskeled,wealherstripped or otherwise sealed.Recessed lighting IC-rated as meeting ASTM E / <br /> Air leakage 402.4 283.Windows and doors=0.30 cfm(sq.ft.Testing or visuai inspection required.Freplaces:gasketed doors& V <br /> outdoor combustion air. <br /> Ceilings/knee walls 4052.1 R-19 space permitting. �/ <br />� Programmable thermostat 403.1 1 Where(orced-air furnace is primary system,programmable thermostat is required. <br />� Air distribution system 4032 Ducts in attics or on roofs insulated to R-8;other ducts R-6.Ducts lested to��=0.03 by a Class i BERS ratec i/ <br />, Heat trap requlred for vertical pipe risers.Comply with efficiencles in Table 403.4.3.2.Provide switch or cleady <br />� Water heaters 4D3.4 marked circuit breaker(electric)or shutoff(gas).Circulating system pipes insulaled to=R-2+accessible manual <br /> OFF switch. <br /> Spas and heated pools musl have vapor-retardant covers or a liquid cover or other means proven to reduce heat <br /> Swimming pool 8 spas 403.9 loss except if 70%of heat trom site-recovered energy.Off/timer switch required.Gas heaters minimum thermal <br />� efficienc =78% 82%after 4/16/13.Heat um ooI heaters minimum COP=4.0. <br /> Sizing calculation performed&attached.Minimum efficiencies per Tables 5032.3.Equipment efficiency verification <br /> Cooling/heating equipment 403.6 required.Special occasion cooling or heating capaciry requires separate syslem or variable capacity system. <br /> Electric heat>10kW must be divided into two or more sta es. <br /> Lighting equipment 404.1 At least 50%of permanently installed lighting fixtures shall be high-efficacy lamps. <br /> 2010 FLORIDA BUILDIIVG CODE—ENERGY CONSERVATION C.5 <br />