Laserfiche WebLink
I , I- . ' � i <br /> ^ 210-52.llwelling Unit Receptacle Oullets. <br /> (n)General Provlsions.L�evcry kitclteu,fainily roo�ry dining rootn,living room,parlc>r,library,den,aun room, <br /> beclroom,recreation room,or similaz room or area of dwelWig units,rcceptacle outlets ehall be installed so that no poinl <br /> along the IIoor line in any wall space is tnore Ilian G it(1.83 tn),measured horizontally,from an ouAet in that epace, <br /> incluciing any wall space 2 II(610 mm)or more in widll�anJ lhe wall epace occupied by fixed panels in exterior walls, <br /> but exclucling sliding panels in exterior walls.1'he wall apace afI'orded by fixed room clividers,sueh as freealancling <br /> bar-type counteis or raiW�gs,shall be included in the 6-it(1.83-m)measurement. <br /> ' (c)Counterlops.Li kilchens and dinuig rooms of dwelling unils,receplacle ouUets for counter spaces ahall be installed <br /> in accordance witli(1)Wrougl►(5)Uelow. <br /> (1)Wall counter space.��receptacle oullet shall be u�slalled at eacl�wall counter space 12 in.(305 mm)or wider. <br /> Receptacle outlets shall be inslalled so Wat no point along tlie wall luie is more Wan 24 ui.(610 tnm),measured <br /> horizontally from a receptacle outlet ui iliat space. <br /> (2)Islatod counter spaces.At least one receptacle ouQet sliall be u�stallcd at each island counter space with a long <br /> , climension of 24 in.(610 mm)or grealer and a sl�ort dimension of 12 in.(305 mm)or greater. <br /> (3)Penlnsular counter space.At least one receptacle outlet shall be installed at each peninaular counter space with a <br /> long climension of 24 ai.(61U nun)or greater at►d a sl►ort dimcnsioii of 12 in.(3U5 mm)or greater.A peninsular <br /> counterlop is menem�ed froin lhe connccGng edge. <br /> (4)Separete spaces.Counleriop spaces separated by range tops,refrigerators,or suilcs shall be considered as separate <br /> countertop spaces in applyuig t1�e reqwremenls of(1),(2),and(3)above. <br /> (5)Receptacle outlet Iocatlon.Receptacle outlels sliall be localed nol more tt�an 18 in.(458 mm)abwe the <br /> countertop.Receptacle outlels shall not be inslalled in a face-up position in tlte worit surfaces or counteriops.Receptacle <br /> outlets rendered not readity accessible by appliances fastened in place or appliances occupying deciicated apace ahall not <br /> Ue coi�sidered as Uiese required oullets. <br /> ' (d)Bathrooms.Li dwelWig wuts,at least one wall receplacle ouUet shall be i�ustalled'ut baduooms adjacet►t to each <br /> - basin location.BaUvoom receptacle outlets shall Ue suppGed by al least one 20-ampere branch circuit.Such circuits shall <br /> have no olher ouQets. See Scction 210-8(a)(1). <br /> Receptacle outlets shall not be u�atalled in a face-up position in We work surfaces or countertops in a batluoom basin <br /> location. <br /> (e)Outdoor OuUets.For a one-fa�nily dwelling u�d each unit of a lwo-family dwelling that is at grade level,at least one <br /> receptacle ouqet accessible at grade level a�id not more than G II,G u�.(1.98 m)above grade shall be installed at the front <br /> and back of tlie dwelling.See Section 210-8(a)(3). <br /> ^ 210-8.Ground-I�ault C(rcuit-Interrupter Prc►tection for Personnel. <br /> (I�PN): See Section 215-9 for gtound-feult circuit-inferruptet protection for personnel on feeders. <br /> (a)Dwelling Units.All 125-voll,siii�le-phase, 15-and 20-ampere receptacles uisialled in the locations apecified below <br /> shall have ground-fault circuit-itdeirupter protecliou for personnel. <br /> (1)Bativooms. <br /> (2)Garages and gracie-level poriiot�s of unfuusl►ed accessory build'uig.g used for atorage or work azeas. <br /> � <br /> _� <br /> ' (6)Kilcl�ens. Where We receplacics are inslalled to serve Uie coui�lerlop sm�faces. <br /> __-J <br />