Laserfiche WebLink
� � <br /> _) -i <br /> � . I <br /> � "'i •.j�I CJ �"*� ,. - . I �c- t .._.,.r• � <br /> � ' ZEPHYR � ILLS FIRE DEPART1i�t�N�T . � � <br /> 1 1,eP6 Y+'6/4s� <br /> , _ Zephyrhills Florida 34248 ' � <br /> T �E I ' <br /> � <br /> , 700 6th Avenue (813) 782-8184 j <br /> ��� QT January 6, 1987 � e / a� � ; <br /> ��{°� � � �� <br /> � Edge Group P.A. ; ` <br /> Fire Chiuf � Tom Dal i a - Pro ject Engi neer , , <br /> tam T. Fenton 444 BUnker Road � ' <br /> West Palm Beach, FL 33405 ` - I ! <br /> sistantChief I ph: (305)585-9307 � <br /> bert Hartwig , • , , i -" <br /> � Re : Proposed East Pasco Medical Center Operations Bldg.(1 story,ap'prox.6,000 �q,ft) <br /> 2500 U.S. Highway 301 North ; � <br /> Zephyrhills, FL 34248 I �, <br /> �I Dear Mr. Dalia, ; <br /> � As per our telephone conversation on 1/6/87, the fol]owing are required I, . <br /> and understood: � � <br /> � 1. Local requirements on smoke detectors : � � <br /> a. One for every 30 fe�et of hallway or part� thereof. - � <br /> - _ b. plus smoke detectors in all storage and �hazard areas. Placement �; <br /> � ' of detectors other than hallways shall bie one detector for each i <br /> f 500 sq. ft. to be protected. Recommend �that a heat detector '; <br /> : be installed in the shop area in lieu of a smoke detector. � <br /> . ; ; <br /> �. ' 2. Fire alarm pull boxes shall be installed at each exit. ; <br /> .. - , � <br /> � 3. Entire fire alarm system shall be tied into hospital system and ', , <br /> � the alarm will be trans�mitted to the Z.F.D. directly or byjprivate � <br /> ' company. ' ' . ', <br /> ; 1 , � :I <br /> 4. Sheet 3 - Drawing A 3 . <br /> It is under5tood that �he outside walls of this section be 5/8 <br /> Type X drywall bo�h sides and finish tight a�gainst the 5/8 Type X � � <br /> on the bar joists. Also, door 113 shall be 20 minute fire rated % <br /> � a d 11 e etrations of inechanical throu h this outside erimeter � <br /> n a n g P <br /> P I i •� <br /> wall shall have fire dampers or smoke dampers. Note - Thi�s�is in � <br /> addition to F.D. now nated on plans. i <br /> , 6. Sheet E-1 - Add an ad¢i�tional Emergency Lig ting pack for General � <br /> Stores and Purchasing Exits. ' � <br /> � , <br /> ; 5. Sheet E-T - Add an addiitional Illuminated Exit sign over P�urchasing � <br /> � exit. i � � <br /> � . <br /> , 7. Add fire extinguisherslper our conversation - Fire rating 2AlOB;C for � <br /> fire extinguishers in Business area, and fire rating of 4A40S;C in . ', <br /> hazard storage areas. <br /> a. 2 fire extinguishe�s in Business area - 2AlOB:C - � � <br /> b. 2 fire extinguishers, one each in Purchasing and Gener�al Stores i <br /> I 4A40B:C. '� i <br /> -� <br /> ; � <br /> . _ _ , <br /> i � � <br />, , � <br /> � � <br /> i � <br /> - � <br />