Laserfiche WebLink
, �i . I ^ , <br /> : �, A' �-� ;. <br /> - �/•'t� R " ��:- :S +` �r} ,1�� <br /> I' <br /> ��;,... -. �,04bYrd�/�a Z�PHYRHILLS FIRE D '� PARTM NT , � , <br /> Zephyrhills Florida 34248 �. <br /> � <br /> � <br /> � 700 6th Avenue ; (813) '�82-8184 <br /> �/ � January 6, 1987 I�, � / a Z , <br /> I •�Rt�`OY'I'C �!J � <br /> . I <br /> � E�dge Group P.A. D� � -� `l��-C�� <br /> FireChief ; Tom Dalia - Project Eng�neer � <br /> iam T. Fenton 4�4 Bunker Road Z� � c�l�-� <br /> • West Palm Beach, FL 33405 - <br /> sIstant Ghief P�h: (305)585-9307 <br /> bert Hartwi� ,- <br /> � Re: ,- Proposed East Pasco Medical Center Operations Bldg. (1 story,appr �x.6,000 sq.ft� <br /> � 2500 U.S. Highway 301 i�orth <br /> . � .Zephyrhills, FL 34248 � <br /> D,ear Mr. Dalia, � <br /> • � --� <br /> � As per our telephone conversation on 1/6/87, the following are r quired � <br /> and understood : � � <br /> , �' 1. Local requirements on smoke detectors : ; � <br /> � a. One for every 30 feet of hallway or pa'rt thereof. � <br /> j '� b. plus smoke detectors in all storage and hazard areas. P acement � <br /> ' of detectors other than hallways shall be one detector f r each ; <br /> 500 sq. ft. to be protected. Recommend t.hat a heat dete tor - <br /> � be installed in the shop area in lieu of a smoke detecto . ' � - � <br /> � (/1�. Fire alarm pull boxes shall be installed at each exit. - � � <br /> ��� Entire fire alarm system shall be tied into hospital system nd <br /> � the alarm will be transmitted to the Z.F.D. di�rectly or by p ivat� <br /> � � -" company. - <br /> v4!�Sheet 3 Drawing � 3 � <br /> � � It is understood that the outside walls of this section be 5/8 <br /> ` Type X drywall bo�h sides and finish tight against the 5/8 pe X <br /> ; on the bar joists. Also, door 113 sha11 be 20 minute fire rated <br /> • and all penetrations of inechanical through this outside peri eter <br /> � wa11 sh�ll have fire dampers or smoke dampers . Note - This4.is in <br /> ' - addition to F.D. now noted on plans. '. .' <br /> � , <br /> , � VCf Sheet E-1 - Add an additional Emergency Lighting pack for G neral , �� " <br /> Stores and Purchasing Exits. . _ � ' � <br /> .; <br /> I � Sheet E-1 - Add an additional Illuminated Exi � sign over Pu chasing ; <br /> e x.i t. � <br /> , �i�l7�Add fire extinguisher$ per our conversation - Fire rating 2 10B;C for ' � <br /> � fire extinguishers in Business area, and fire rating of 4A4 B.;C in , ' . <br /> � � hazard storage areas: . � - <br /> � a. 2 fire extinguishers in Business area - 2llOB:C . , - � <br /> ; b. 2 fire extinguishers , one each in Purchas ng and General Stores� , <br /> 4A406:C. <br /> � <br /> , , <br /> ; . <br /> � <br /> � � <br />