My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7050 GALL BLVD (46)
Zephyrhills
>
Building Department
>
Building Plans
>
7050 GALL BLVD (46)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/12/2017 1:25:42 PM
Creation date
4/12/2017 1:20:01 PM
Metadata
Fields
Template:
Building Plans
Street #
7050 GALL BLVD
Location
GALL BLVD
Description
DIETARY EXPANSION
Owner
EAST PASCO MEDICAL CENTER
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
.• i � �� <br /> i <br /> • � Page 2 I <br /> ; July 11, 1996 I <br /> � ; Mr. James R. Gregory � <br /> , i 1 <br /> � �� A-3 Revise door swing of Door 116D-1 to swin in <br /> g <br /> i direction of exit flow. i <br /> �� Respoase: � The swing of Door 116D-1 has now beea reversed. <br /> '� Copy of Zastruction Memo #1 to Contractor <br /> � attached. <br /> � <br /> �A-4 See Response to A-2 and A-4 above. <br /> I , � <br /> � ;A-5 Magnetic locks on exterior walkway aecurity doors � <br /> must disengage on loss of power or fire alarm. <br /> I ' <br /> I ,Respoase: on submitted Drawing A-1, in ^clouded„ note at <br /> ; each opening it calls for the magaetic locks to <br /> �, � unlock on Fire Alarm signal, this is se beiag. <br /> i , � iastalled. See also Note 2, Sheet E-3, which is <br /> i <br /> � aow corrected to show the additioaal magnetic <br /> locks at Doors 109D, 114D and 115D. Magnetic <br /> j locks are iahereatly safe on power failure, they <br /> � simplp go dead. Or, if coanected to geaerator, <br /> �I thep continue to fuactioa as iateaded. <br /> , � <br /> ; i �A-6 A slidinq Stanley-type door of the miniunum width <br /> of 44 inches clear opening will be acceptable as <br /> I � - <br /> a "smoke resistant^ door in a "smoke-tight" <br /> corridor wall. However, such d�r must have a <br /> ' breakaway feature, and, if a required exit, must <br /> be located in an alcove so that the breakaway <br /> � will be outward in the direction �of exit travel. <br /> � Response: Kitchea Door lO1D (Serviag to Corridor) is aot aa <br /> �Exit«, it is, however, an egress door from a ' ' <br /> i � large area. As such, we have adde� an ezit light <br /> , over it. The door itself has beea modified to a <br /> � � staadard bi-parting power door Nith breakaway <br /> ; features opeaing fa the outward; directfon. Aa <br /> ' alcove has beea created so that ia such fastance <br /> ezit width is aot eacroached'. Sheet A-3 <br /> , ' attached. � <br /> ' Responses by the Electrical and Mechanical Engineers are attached <br /> ''� also, as are corrected, signed and sealed drawings and the <br /> j Instruction Memo to the Contractor to initiate the work. <br /> I I <br /> � ' <br /> , , �, <br /> , � Very truly yours, � <br /> , '�, <br /> � <br /> I <br /> � � <br /> Donald R. Edg ' I <br /> Architect <br /> � - <br /> � � I <br /> 'I� � <br /> Ct�AHCAEPNC.711 _ - <br /> ' � - - <br /> - � - - . , . - - - - - - - <br /> . ,- .:._�. : .�._....,�- - - - - <br /> - - -' ---. ,. .. ;. . .�. - - - -- - - -- - - --- -- <br /> . ..- _ ,.. <br /> - - . .. _ , <br /> , -- --- �- - . . -' - <br /> � • -- � .- - ,_. _ , <br />
The URL can be used to link to this page
Your browser does not support the video tag.