My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7050 GALL BLVD (46)
Zephyrhills
>
Building Department
>
Building Plans
>
7050 GALL BLVD (46)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/12/2017 1:25:42 PM
Creation date
4/12/2017 1:20:01 PM
Metadata
Fields
Template:
Building Plans
Street #
7050 GALL BLVD
Location
GALL BLVD
Description
DIETARY EXPANSION
Owner
EAST PASCO MEDICAL CENTER
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> . � <br /> . � � <br /> '; '�� COLWILL ENGINEERING, INC.% <br /> � ', electrical engineers and construction managers � <br /> ; � <br /> ; ' i <br /> � I <br /> July 10, 1996 �, I <br /> � � I <br /> I I <br /> Tlie Edge Group i <br /> 4�4 Bunker Road � <br /> West Palm Beach,Florida 33405 � <br /> � i <br /> Attention: Mr. Donald R. Edge <br /> � <br /> Reference: East Pasco Medical Center ; <br /> � �Dietary Expansion/Courtyard(Kitchen Tra.yline Modified} <br /> �, 'Log No.H-425-W/Con No_ Exempt#9600018 <br /> Dear Mr. Edge:, � <br /> � <br /> ; <br /> � <br /> � <br /> We are writing to respond to the State of Florida.Agency for Health Care Administration comments dated <br /> June 6, 1996 forithe above referenced project. <br /> ' � I <br /> Comment E-1: �, Coordinate the exit light locations with the life safety plan. <br /> � ', ' <br /> � � <br /> Response: � Have complied. Refer to drawing E-2 for new locations of exit lights. <br /> � , <br /> Co Imment E-2: ; Provide critical branch lighting in serving room 1010. <br /> � , <br /> Response: � Have complied. Refer to drawing E-2 for loca.tion and circuitry of critical lighting in <br /> � this room. ' <br /> I + � <br /> Comment�E-3: ; Indicate the branch circuit for the magnetic door lock ower su hes. <br /> � ' i P PP <br /> � , <br /> dZesponse: Have complied. Refer to drawing E-3 for circuitry of magnetic door locks. <br /> , <br /> Coinl ment�4: �; Connect the automatic doors to the equipment branch. , <br /> ;I <br /> Response: ' Ha.ve complied. Refer to drawing E-3 for new circuitry of automatic doors. <br /> Co I ment E-5: � Provide visual fire alarm devices in the Consultation Room 1070 and Dietitians Room <br /> � �� 1069. � <br /> i i <br /> Response: , Ha've complied.Refer to dra��ing E-3 for new location of visual fire ala.rm devices in <br /> � ; this area. i <br /> � i <br /> Conr'ment�6: ' Verify that the new addition falls under the cone of protection of tlie adjacent three <br /> i � story structure. <br /> , I � <br /> i <br /> Response: ! Using the 150'rolling sphere method,the new addition is protected!by the existing <br /> ' lightning protection system. <br /> I <br /> � 5804 a breckenridge parkway • tampa, florida 33610 • (813) 6',26-1646 <br /> � <br /> - �, �� � - - <br /> i . . - , . - � - = <br />
The URL can be used to link to this page
Your browser does not support the video tag.