Laserfiche WebLink
i <br /> ' � � <br /> J � 'I <br /> .� <br /> r <br /> - i <br /> Sheet A0.01 —Lii e Safety Plan—Ground Floor: <br /> 1. Incorporate the addition of Notice of Acceptance note as indicated on the attached drawing A0.01, dated <br /> April 17, 2002, Delta No. 1. <br /> 2. Incorporate the notation changes as indicated on the attached drawing A0.01, dated April 17, 2002,Delta <br /> No. 1. I <br /> Sheet A0.02—L'ife Safety Plan—First Floor: <br /> 1. Incorporate the numeric change in the exiting tabulation chart as indicated in the attached drawing A0.02, <br /> dated Ap'i 1 17, 2002, Delta No. 1. - <br /> 2. Incorporate the existing floor plan changes as indicated on the attached drawing A0.02, dated April 17, <br /> 2002, Del�a No. 1. <br /> Sheet A0.03 —Lif I Safety Plan—Second Floor: <br /> � <br /> l. Incorporate the existing floor plan changes as indicated on the attached drawing A0.03, dated April 17, <br /> 2002, Delta No. 1. <br /> Sheet A0.04—Lifl I Safety Plan—Third Floor: <br /> � <br /> 1. Incorporate the existing floor plan changes as indicated on the attached drawing A0.04, dated April 17, <br /> 2002,Delta No. 1. <br /> i <br /> Sheet A1.01 —Noted and Dimensioned—First Floor: <br /> 1. Incorporat I the floor plan changes and wall rating changes as indicated on the attached drawing A1.01, <br /> dated April�17, 2002,Delta No. 1. <br /> 2. Incorporate the addition of an egress door on the north side of the dining room as indicated on the <br /> attached drawing A1.01, dated April 17,2002,Delta No. 1. <br /> i <br /> 3. The set of�windows that were located in the wall of the corridor will not be installed, and the existing <br /> section of�wall at the area will not be demoed as indicated in the attached drawing A1.01, dated April 17, <br /> 2002, Delta�No. 1. <br /> 4. The existing corridor door frame and wall to the servery are to be demoed and replaced to maintain shaft <br /> wall fire ratmg as indicated in the attached drawing A1.01, dated April 17,2002,Delta No. 1. <br /> �, <br /> 5. The existin�g door and frame that connects the kitchen to the servery is to be demoed and replaced with a <br /> new door to maintain the shaft wall rating as indicated on the attached drawing A1.01, dated April 17, <br /> 2002, Delta o. 1. <br /> � <br /> 6. The windows on the north side of the room have been modified for fire rating reasons as indicated on the <br /> attached drawing A1.01, dated April 17,2002, Delta No. 1. <br /> Sheet A1.02—Roof Plan—Second Floor: <br /> 1. Incorporate,Ihe roof plan changes that incurred due to the movement of the rooftop air handling unit as ' <br /> indicated on the attached drawing A1.02, dated April 17, 2002,Delta No. 1. j <br /> � �� <br /> REVISION NO. 1 �� PAGE 2 JQB NO. 02016.00 � <br /> �. I <br />