My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
5906 GREENBRIAR DR
Zephyrhills
>
Building Department
>
Building Plans
>
5906 GREENBRIAR DR
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2017 10:05:10 AM
Creation date
4/28/2017 10:02:42 AM
Metadata
Fields
Template:
Building Plans
Street #
5906 GREENBRIAR DR
Location
GREENBRIAR DR
Contractor
RYMAN CAONSTRUCTION
Description
WEDGEWOOD MANOR LOT 57
Building Plans - Permit #
1614
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� ! i <br /> � Electrica! Notes <br /> 2002 Electrical Code <br /> Ryr�an Construction <br /> ; 5906 Greenbriar <br /> 210.8(A): All 125-volt,single-phase, 15-and 20-ampere receptacles installed in the locations <br /> � � specified in(1)through(8)shall have ground-fault circuit-interrupter protection for <br /> � personnel. <br /> (3)Outdoors <br /> � (6)Kitchens—where the receptacles are installed to serve the countertop surfaces <br /> I <br /> 210.11(C)(3): In addition to the number of branch circuits required by other parts of this section,at least <br /> � � one 20-ampere branch circuit shall be provided to supply the bathroom receptacle <br /> outlet(s). Such circuits shall have no other outlets. <br /> Exception: Where the 20-ampere circuit supplies a single bathroom, outlets for other <br /> I � equipment within the same bathroom shall be pe�mitted to be supplied in acco�•dance <br /> with 210.23(A) <br /> 210.12(B): All branch circuits that supply 125-volt,single phase, 15-and 20-ampere outlets <br /> (RECEPTACLES,LIGHTS,SMOKE DETECTORS)installed in dwelling unit <br /> bedrooms shall be protected by an arc-fault circuit interrupter listed to provide protection <br /> of the entire branch circuit. <br /> � <br /> 240.24(B): ' � Each occupant shall ready access to all overcurrent devices protecting the conductors <br /> supplyingthatoccupancy. <br /> � 250.50: If available on the premises at each building or structure served,each item in <br /> � 250.52(A)(1)through(A)(6)shall be bonded together to form the grounding electrode <br /> system <br /> . <br /> 210.52(A)(i): Receptacles shall be installed so that no point measured horizontally along the floor line <br /> in any wall space is more than 1.8 m(6 ft)from a receptacle outlet. <br /> i <br /> 210.52(C)(1): A receptacle outlet shall be installed at each wall counter space that is 300 mm(12 in.)or <br /> , ! wider.Receptacle outlets shall be installed so that no point along the wall line is more <br /> � than 600 mm(24 in.)measured horizontally from a receptacle outlet in that space. <br /> 406.8(A): '� , A receptacle installed outdoors in a location protected from the weather or in other damp <br /> � locations shall have an enclosure for the receptacle that is weatherproof when the <br /> , receptacle is covered(attachment plug cap not inserted and receptacle covers closed). <br /> 406.8(B)(1): 15-and 20-ampere, 125-and 250-volt receptacles installed outdoors in a wet location <br /> shall have an enclosure that is weatherproof whether or not the attachment plug cap is <br /> inserted. <br /> I <br /> � � <br /> � <br /> � ; i 10/28/02 <br /> ,; I I 2:02 PM <br /> � <br />
The URL can be used to link to this page
Your browser does not support the video tag.