My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
37609 LAUREL HAMMOCK DR
Zephyrhills
>
Building Department
>
Building Plans
>
37609 LAUREL HAMMOCK DR
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/2/2017 11:50:09 AM
Creation date
5/2/2017 11:47:48 AM
Metadata
Fields
Template:
Building Plans
Street #
37609 LAUREL HAMMOCK DR
Location
OAK RUN
Contractor
RYMAN CONSTRUCTION
Description
SING FAMILY DWELLING
Building Plans - Permit #
0433
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
,( _._....._�._ <br /> mm) or wider. Receptacle outlets shall be installed so that no point.along the wall.line.is more than 24 in. (610 � <br /> min),measured horizontally from a receptacle outlet in that space: � � <br /> (2) Island Counte�Spaces.At least one receptacle outlet shall be installed at each island counter space with a <br /> long dimension of 24 in. (610 mm) or greater and a short dimension of 12 in.�(305 mm) or greater.� <br /> (3) Peninsular Counter Spaces.At least one receptacle outTet shall be installed at each peni.nsular.counter <br /> space with a long dixnension„of 24 in. (610 mm) or greater and a short dimension of 12 in. (305 rrim) or greater. � <br /> A peninsular countertop is measured from the connecting edge. , , _ <br /> (4) Separate Spaces. Countertop spaces separated by range tops,refrigerators, or sinks shall be considered as <br /> - separate countertop spaces in applying the requirements of(1), (2), and(3). � <br /> (5) Receptacle Outlet Location.Receptacie outlets shall be located above,but not more than 18 in. (458 mm) <br /> above the countertop:Receptacle outlets shall not be installed in a face-up position in the work surfaces or � <br /> countertops. Reeeptacle outlets rendered not readily accessible by appliances fastened in place or appliances <br /> occupying dedicated space shall not be considered as these required.outlets.;;���� � ; , <br /> Exception: To comply with the conditions as specified in (a) or_(b); receptacle outlets shall be p,e'rmitted to be <br /> mounted not more than 12 in. (305 mm) below the cauntertop. Receptacles mounted below the counteYtop in <br /> accordance with this exception shall not be located where tlie countertop extends more than 6 in. '(153.mm) � <br /> � _ . . <br /> beyond its suppof-t base. , � • <br /> a. ConstYuction for the physically impaired , � , � <br /> b. On island and peninsul'ar countertops where the countertop'is flat across its entire surf'ace (no <br /> backsplashes, dividers, etc.) and there are no mettns to mount a receptacle within 18 in. (458 mm), above the <br /> countertop, such as an overhead cabinet ' <br /> (d) Bathrooms. In dwelling units; at least one wall receptacle outlet shall be installed in bathrooms within 36 <br /> in. (914 mm)of the outside edge of each basin. The receptacle outlet shall be located on a wa11 tha�is adjacent <br /> � to the basin location. See Section 210-8(a)(1). � <br /> � <br /> Receptacle outlets shall not be installed in a face-up position in the work surfaces or countertops in a bathroom <br /> basin location.:�Ca,m„�;,�a�y� , <br /> (e) Outdoor Outlets.For a one-family dwelling and each unit of a two-family dwelling that is at g'rade level, at <br /> least one receptacle outlet accessible at grade level and not more than 61h ft(1.98 m)above grade'sha11 be � <br /> installed at the front and back of the dweiling. See Section 210-8(a)(3). ��,,,,,,�c��� <br /> (�. Laundry Areas.In dwelling units, at least one receptacle outlet shall be installed for the laund,ry. <br /> .t�co�,=� , i _ <br /> Ezception No. 1:In a dwelling unit that is an a�artment or living area in a multifamily building where <br /> laundry facilities areprovided on thepremises that are avaalable to all building occupants, a laundry <br /> receptacle shall not be required. ' <br /> - , � � <br /> Exception No. 2:In other than one family dwellings where laundry facilities are not to be install`ed or � <br /> permitted, a laundry recepfacle shall not be required. ' ' � ! ' <br /> (g) Basements and Garages.For a one-family dwelling, at least one receptacle outlet, in addition fo any <br /> - provided for laundry equipment, shall be installed in each basement and in each attached garage,-and in each <br /> ' i <br /> , � <br />
The URL can be used to link to this page
Your browser does not support the video tag.