My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6145 ABBOTT STATION DR
Zephyrhills
>
Building Department
>
Building Plans
>
6145 ABBOTT STATION DR
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/4/2017 2:05:57 PM
Creation date
5/4/2017 2:00:39 PM
Metadata
Fields
Template:
Building Plans
Street #
6145 ABBOTT STATION DR
Location
ABBOTT STATION DR
Contractor
GOLD MEDALLION HOMES INC
Description
DAYCARE
Owner
LITTLE FRIENDS SCHOOLHOUSE
Building Plans - Permit #
9819B
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
704.2.2-704.4.1 <br /> _ ed in steel frames. There is no restriction on the total TABLE 704.2.4 = " I <br /> number of such panels in any barrier. FIRE RESISTANCE RATING OF EXIT ACCESS CORRIDORS = <br /> i <br /> - Exception: Smoke barriers in Group I Restrained OCCUPANCY OCCUPANT FIRE RESISTANCE _ <br /> __ occupancies shall be permitted to be constructed of LOAD RATING(hours) _ � <br /> = minir�um 0.10 inch(2.5 mm)�thick steel. Sprinklered Unsprinklered ° <br /> _ 704.2.2 Partition requirements by occupancy A,s,r,tv1,S less than 30 0 0 = <br /> __ 704.2.2.1 Group I Restrained A 30 or more t 1 = <br /> : 704.2.2.1.1 Smoke barriers shall be constructed in B,F,M,S 30 or more 0 t = <br /> _ accordance with 704.2.1.5. R1,R2,R3 less[han 10,Note I 0 0 = <br /> Rl,R2 10 or more,Note 1 1/2 1 = <br /> 704.2.2.1.2 All interior partitions in Type I and Type R.4 16 or less o '0 _ <br /> II construction shall be of noncombustible construc- R4 more than 16,Note 1 0 '� 5 <br /> tlOri. E Note 2 1 l ° <br /> I Unrestrained All 0 N/A '" - <br /> = I Restrained All 0 0,Note 3 <br /> = 704.2.2.2 Gro�p T Unrestr�ined.Smoke barriers sllall H A(I ► 1 ' <br /> _ have a minimum 1-hour fire resistance rating and be = <br /> = constructed in accordance with 704.2.1.5. Notes: ' <br /> _ 1. Corridors within guest rooms or dwelling units need not be ratcd. = <br /> = 704.2.2.3 Group R Residential. NOIIf1I'e I1te(� PBIti- 2. Corridors need not be rated in Group E occupancies with rooms used = <br /> = tions may be constructed w1[h1n small residential ei�her for instruction with at]east one exit cloor directiv to the exte- _ <br /> = iior at ground level or for assembly purposes with at least one-half of = <br /> _ care/assisted living faCllltles (Group R4 Sm811 t e require exus directly to the exterior at ground leve. = <br /> Facility), one and two family dwellings and within 3. 't1nSj�nn ere use condition s�a ave exit access c cridors of i- _ <br /> individual dwelling units unless required by Table 600. .hour fire resistance. : <br /> The tenant separation in a two family dwelling shall <br /> comply with 704.3. 704.3 Tenant Cre separation <br /> _ - 704.3.1 In a building or portion of a building of a single <br /> _ Exception: Shaft enclosures in Group R4 occupan- occupancy classification, when enclosed spaces are pro- ' <br /> _ cies shall be enclosed and protected in accordance vided for separate tenants, such spaces shall be separated � <br /> = with the requirements of Table 705.1.2. by not less than 1-hour fire resistance. <br /> 704.2.3 Partitions within tenant space Exception: In Group B and Group S occupancies,par- <br /> 704.2.3.1 Partitions dividing portibns of stores; offices titions not rated for fire resistance may be used to sep- <br /> or similar places occupied by one tenant only,which do arate tenants provided no area between partitions rated <br /> not establish an exit access corridor serving an occu- at 1 hour or more exceeds 3,000 sq ft(278.7�m2). <br /> pant load of 30 persons or more, and partial partitions, <br /> may be temporary or permanent and constructed in 704.3.2 In buildings with usable crawl spaces, tenant sep- <br /> accordance with 609 without fire resistance, provided aration walls required to have a fire resistance rating shall <br /> that; extend from the underside of the floor to th'e ground <br /> 1. Their location is restricted by their method of below. A suitable foundation shall be provided at grade <br /> construction or by means of permanent tracks, level. <br /> guides or other approved methods. <br /> 2. Flammability shall be limited to materials having Exception: The wall need not be extended��vhen the <br /> an interior finish classification as set forth in iloor above the crawl space has a minimum 1-hour fire <br /> * Table 803.3 for rooms or areas. resistance rating. <br /> = 704.2.4 Exit access corridors. Fire resistance rating of 704.4 Townhouse fire separation <br /> _ exit access corridors shall be in accordance with Table 704.4.1 Each.townhouse shall be considered a separate <br /> _ 704.2.4. building and shall be separated from adjoining iownhous- <br /> es by a party wall complying with 704.4.2 or by!the use of <br /> separate exterior walls meeting the requirements of Table <br /> 600 for zero clearance from property lines as required for <br /> the type of construction. Separate exterior walls shall <br /> include one of the following: <br /> 1. A parapet not less than 18 inches (457 mm) above <br /> —� the roof line. <br /> 2. Roof sheathing of noncombustible mate'rial or fire � <br /> retardant treated wood,for not less than a 4 ft(1219 1+ <br /> � <br /> 92 STANDARD BUILDING CODE°1997 <br />
The URL can be used to link to this page
Your browser does not support the video tag.