38113 MARKET SQ
Zephyrhills
>
Building Department
>
Building Plans
>
38113 MARKET SQ
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/13/2017 8:01:03 AM
Creation date
5/13/2017 7:28:02 AM
Metadata
Fields
Template:
Building Plans
Street #
38113 MARKET SQ
Location
MARKET SQ
Contractor
HINSON BUILDING CORP
Description
INTERIOR BUILD OUT FOR MRI UNIT
Owner
FLORIDA MEDICAL UNIT
Building Plans - Permit #
8889B
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
179
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I. Piping shall have sufficient number of flanges or unions for • <br /> convenient installation and removal of piping and equipment. <br /> J. Remake or replace defective, leaking, or otherwise unsatisfactory <br /> joints or material. Peening, caulking, or doping of piping is not <br /> permitted. <br /> K. Install piping to prevent stresses and strains to piping and hangers <br /> from expansion or contraction. Provision for proper loops, offsets, <br /> or expansion joints shall be responsibility of Contractor. Make�: <br /> provision for servicing and removal of equipment without � <br /> dismantling piping. ' <br /> 3.2 Not used. I <br /> � <br /> 3.3 NON-RATED PARTITIONS: � <br /> , <br /> A. Piping shall pass through the walls insulated or noninsulated as <br /> specified. Wall should be finished to fit neatly around the piping. <br /> Firestopping is not required at non-rated partitions. ; <br /> 3.4 PIPE SLEEVES ; <br /> � • <br /> A. Pipe sleeves shall be Schedule 40 or 18 gage steel. Sleeves sliall <br /> extend 1-1/2" in excess of partition depth on each side. I <br /> � <br /> 1. Piping requiring sleeves: ; <br /> Sprinkler(Fire Protection). � <br /> Heating hot water � <br /> Domestic hot and cold water , <br /> Copper pipes thru masonry walls � <br /> j <br /> B. Provide chromium-plated escutcheon plates for exposed , <br /> uninsulated pipes projecting through floors or walls in finished <br /> spaces. Mechanical rooms and janitor closets are not considered <br /> "fuushed" spaces. ; <br /> 3.5 VALVE ACCESS � <br /> A. Locate all shutoff and control valves for easy access and opeiation. <br /> Where valves must necessarily be located in enclosed spaces, they <br /> sha11 be provided with access panels of sufficient size for ; <br /> operation. Furnish these access panels to proper trades for � <br /> installation. � <br /> : • <br /> � <br /> ICT 99184 � <br /> 15060 - 6 <br />