My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38113 MARKET SQ
Zephyrhills
>
Building Department
>
Building Plans
>
38113 MARKET SQ
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/13/2017 8:01:03 AM
Creation date
5/13/2017 7:28:02 AM
Metadata
Fields
Template:
Building Plans
Street #
38113 MARKET SQ
Location
MARKET SQ
Contractor
HINSON BUILDING CORP
Description
INTERIOR BUILD OUT FOR MRI UNIT
Owner
FLORIDA MEDICAL UNIT
Building Plans - Permit #
8889B
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
179
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i � <br /> � <br /> � <br /> • � C. Provide A-frame cooling coil with copper tubes, and aluminum <br /> fins with a maximum of 12 fins/inch. Test coils at 320 psig air <br /> , pressure under warm water. Mount coil assembly in a condensate <br /> � drain pan coated with a UL-listed rust preventative polymer <br /> � coating, minimum 3/16" thick. <br /> � <br /> D. Provide heavy duty, low watt density electric reheat coils with <br /> , fintube construction. Provide UL-listed safety switches for the <br /> ; reheat coil. <br /> i <br /> i E. Condenser shall be remote-mounted, air-cooled type with direct- <br /> i driven propeller fans, and copper tube-aluminum fin coil mounted <br /> ; in a weatherproof, heavy metal enclosure with baked enamel finish. <br /> F. Include infra-red humidifier utilizing high intensity quartz lamps <br /> � mounted above stainless steel evaporator pan. Arrange pan to be <br /> serviceable without disconnecting water lines, drain lines or <br /> � electrical connections. Provide liquid level control and emergency <br /> overflow. Use distilled condensate from cooling coil as primary <br /> � water supply and use bypass air over humidifier. Provide <br /> � '� automatic flushing system for pan. <br /> � I <br /> � � G. Filters shall be integral part of system and shall have ASHRAE <br /> � efficiencies shown on drawings when tested in accordance with <br /> ASHR.AE standard 52-76. Pressure drops across filters are internal <br /> � losses. <br /> �' <br /> � H. Control System: <br /> j 1. Provide solid-state control system with start-stop button, <br /> manual reset circuit breakers, solid-state temperature and humidity <br /> conirol modules with adjustable set points. <br /> 2. Provide contacts for remote alarm of the following: <br /> i <br /> i a. Air flow loss. <br /> i <br /> b. Filter pressure drop too high. <br /> c. Return air temperature too high. <br /> I d. Return air humidity too high. <br /> I • PART 3I-EXECUTION <br /> � I <br /> � <br /> i ICT 991�84 <br /> i 15764 - 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.