My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
37343 LAUREL HAMMOCK DR
Zephyrhills
>
Building Department
>
Building Plans
>
37343 LAUREL HAMMOCK DR
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/15/2017 10:21:11 AM
Creation date
5/15/2017 10:18:13 AM
Metadata
Fields
Template:
Building Plans
Street #
37343 LAUREL HAMMOCK DR
Location
OAK RUN
Contractor
RYMAN CONSTRUCTION
Building Plans - Permit #
0512
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I' � ' a � <br /> . (a)Dwelling IJnits. In dwelling units; lighting outlets sha11 be installed in accordance with(1), (2), and(3). <br /> _ (1)Habitable Rooms.At least one wall switch-controlled lighting outlet sha11 be installed in every habitable <br /> _ room and bathroom. . <br />�, Exception No. 1: I. �other than kitchens and bath�oonzs, one or moYe receptacles controlled by a wall switch <br /> shall be�eYmitted in l'ieu of lighting outlets. ,;�c� <br /> Excep�'on No. 2: Llighting outlets shall be pernZitted to be controlled by occupancy sensors that a�e (1) in <br /> addition�to wall switches or (2) located at a customary wall switch location and equzpped with a manual <br /> override,'ithat will alloi the sensor to function as a wall switch. <br /> (2)Additional Loca�ions. At least one wa11 switch-controlled lighting outlet shall be insta11ed in ha11ways, <br /> stai.rways, attached garages, and detaclied garages with electric power; and to provide illumination on the <br /> exterior side of outdoor entrances or exits with grade level access. A vehicle door in a garage sha11 not be <br /> i consider�'�d as an outc�oor entrance or exit. Where lighting outlets are installed in interior stairways,there shall be <br /> a wall svuiitch at each floor level to control the lighting outlet where the difference between floor levels is six <br /> ,l i <br /> -, steps or more.;.c��;�,���g. <br /> Exception: In hall I�s, stai�vays, and at outdoor entrances, remote; central, or automatic control of lighting <br /> �I <br /> shall be permitted. <br /> � <br /> (3) Stor�ge or Equi ment Spaces. For attics,underIloor spaces;utility rooms, and basements, at least one <br /> � <br /> ligliting outlet contai�ng a switch or controlled by a wall switch shall be installed where these spaces are used <br /> for storage or con �equipment requiring servicing. At least one point of control shall be at the usual point of <br />' entry to these spaces. The lighting outlet shall be provided at or near the equipment requiring servicing. <br /> ;rc��c�. <br /> � (b) Gues,t Rooms.A ileast one wall switch-controlled lighting outlet or wall switch-controlled recepta.cle shall <br /> be installed in guest rooms in hotels, motels, or similar occupancies. - <br /> �` ' � <br /> (c) Othe�Locations.For attics and underfloor spaces contairiing equipment requiring servicing, such as <br /> heating, ;air-conditioning, and refrigeration equipment, at least one lighting outlet containing a switch or <br />� controlle'd by a wall�witch sha11 be installed in such spaces. At least one point of control shall be at the usual <br /> point of entry to these spaces. The lighting outlet shall be provided at or near the equipment requiring servicing. <br /> ��240-24.Location in or on Premises <br /> (a) Accessibility. Overcurrent devices shall be readily accessible unless one of the following applies.;�c��a,u <br /> - 1. For busways, as provided in Section 364-12. <br /> 2.For supplemenitary overcurrent protection, as described in Section 240-10. <br /> � I <br /> 3. For overcurrent devices, as described in Sections 225-40 and 230-92. <br /> 4. For overcurrent devices adjacent to utilization equipment that they supply, access sha11 be permitted to be <br /> ���_ <br /> - by portab'le means.�rc�„�,�a <br /> � <br />� , (b) Occupancy. Eacli(occupant shall have ready access to all overcurrent devices protecting the conductors <br /> supplying that occup�ncy. Where electric service and electrical maintenance are provided by the building � <br /> management and where these are under continuous building management supervision,the service overcurrent <br /> devices and feeder overcurrent devices supplying more than one occupancy shall be permitted to be accessible <br /> to only authorized management personnel in the following: <br /> �i � <br /> 1.In multiple occupancy buildi.ngs <br /> , � <br /> 2. For guest room I of hotels and motels that are intended for transient occupancy _ <br /> . I <br /> �t � <br />
The URL can be used to link to this page
Your browser does not support the video tag.