Laserfiche WebLink
� - <br /> �_ `� <br /> 1r / <br /> _irlf <br /> Excegtion:�eceptacles that are nat reudily accessihle and ttre su�plied,ft•arn a.dedicated branch circuit.f'or <br /> Y <br /> electric snaw-melting ar deicing equipment shull be pennitted to be znstalled in accordance with.the applicabl'e <br /> provisions af�4�ticle 42b. '�� <br /> f <br /> 210-11.Branch Circuits Itequired � <br /> Branch circuits for lighting and for appliances,including motor-operated appliances, shatl be provide.d tp supply <br /> the loads computed in accordance with Section 220-3. In addition,branch circuits shall be pravided for specific <br /> loads not cavered by Section 220-3 where required elsewhere in this Code and for dwelling unit loads as <br /> specified in{c).���'�„�� <br /> �a)Number of Branch Circuits.The minimum number of branch circuits shall be detennined from the tatal <br /> computed laad and the size or rating of the circuits used. In all installations, the number of circuits shall be <br /> sufficient to supply the load served. In no case shall the load on any circuit exceed the maximum�specifiied by <br /> Section 220-4. � <br /> (b) Load Evenly Proportioned Among Branch Circuits.Wh�rre the load is computed on a <br /> volt-amperas/square foat{0.093 m�)basis,the wiring system up to and including the branch-circuat <br /> - panelboard(s)shall be provided to serve not less than the calculated load. This load shall be evenl�proportioned <br /> among multiautlet branch circuits within the•panelboard(s). Branch-circuit avercurrent devices an�d circuits need <br /> ozily be iustalleci to serve the connected Iaad. ; <br /> {c)Dwelling Unrts: � <br /> (1) Small Appliance Saranch Circuits.In addition to the number of branch circuits required by other parts af ' <br /> tJais section, two ar more 20-ampere small-appliance branch circuits shall be-provided for all receptacle outlets <br /> specified by Sectian 210-52(b). <br /> {2)�.aundry Branch Circuits.In addition to the nurnber of branch circuits requzred by other part',s of this <br /> section, at least one additiona120-ampere bran.ch circuit shall be provided to supply the laundry receptacle <br /> outlet{s)required by Section 2 2 0-52(�-'I'his circuit shali have no other outiets. <br /> {3) �athroom Branch Circuits.,In addition to the number of branch circuits required by other pai�ts af�zis <br /> section, at least one 20-aznpere branch circuit shall be provided to supply the bathroom receptacle'outlet(s). <br /> Such circuits shall have no other autlets. <br /> Exceptir�n: I�here the 20-ampere circuit supplies a single bathroom, outlet�,f'o�°othe�er�uipmenx`within the <br /> same bathroam shall be permitted to be supplied in accordance with Section 210-23(a). <br /> FPN: See Examples Dl(a),D1(b),D2(Ya),and D4(a)in Appendix D. � <br /> 210-52. Dwelling Unit Receptacle Outlets� <br /> Receptacle-outlets required by this section shall be in add'ztion to any receptacle that is part af a lighting fixture <br /> or appliance,located wi#hia.cabinets or cupboards, or Iocated more than. S112 ft{1,68 m) abave the�floor. <br /> P�rmanently installed electric baseboard heaters equipped with factory-installed receptacle outlets;or outlets <br /> provided as a separate assembly by the manufacLurer shall be permitted as the required outlet or o�tlets for the <br /> wa11 space utilized by such permanentiy installed heaters. Such xeceptacie aut�e#s shall not be conr�ected to the <br /> � heater circuits. <br /> y <br /> ; <br /> � �� � <br /> � ; � <br />