Laserfiche WebLink
i _ , <br /> ;�,`; - �-,� ; � .. ,��P�������S ����� D��A�'�T���I�� • <br /> - ti°g��~�f��s� <br /> ` � ' - <br /> Zephyrhills Florida 34248 <br /> � <br /> 700 6th Avenue (813) 782-8184 <br /> � <br /> January 30, 1989 <br /> FI�',�p�y� <br /> Robert F. Green, Project Engineer �I <br /> Fire Chief Proposed Zephyrhills Bottled Water Company � <br /> William T. Fenton %,� � <br /> �1f.�� Show electrically operated smoke detectors for all halls/corridors <br /> Assistant Chief lf and storage areas in entire West Office Areas. �, <br /> Robert Hartwig � <br /> 2. Show location of Fire Extinguishers for area mentioned above, plus <br /> manufacturing area. See NFPA ��10. � <br /> 3. Question, If J1 and K1 lights are battery operated emergency lights, 1 <br /> will J1 and K1 give the necessary candle power lighting at all walk � <br /> areas to exits(halls/corridors)? � <br /> 4. Show Fire Alarm System and pull boxes at each designated exit from <br /> structure. Fire Alarm System shall consist of spr.inkler system, <br /> smoke detectors, and pull boxes - show how system is supervised and <br /> how alarm is transmitted to Fire Department. (Private company is � <br /> acceptable.) See NFPA 101 28-1.7, 28-3.4.1, and 7-6. � <br /> 5. All four doors from West Office Areas to manufacturing area shall be <br /> a Class B 45 minute fire-rated door and assembly with door closures. <br /> 6. Designated exit door on South side shows an overhead door, this is not , <br /> acceptable. Exit on South side shall be a side-hinged door that swings <br /> to the outside. <br /> 7. Sprinkler system shall conform fully with NFPA 13 and SBC 901.8. All <br /> areas and rooms within the structure shall have proper spacing of <br /> sprinkler heads. , �I <br /> 8. Submit floor plans showing all locations of sprinkler heads and types '�I <br /> in all enclosed areas inside structure (Office Area, Supezvisor's <br />, 2nd Floor location, etc.) , <br /> �� <br /> 9. Sprinkler heads in enclosed office areas other than Ordinary Group III <br /> to be classified as Light Hazard shall be 165°F heads, and spaced no � <br /> � ! more than every 200 sq. ft. i � I <br /> ; � <br /> ,I 10. i Show Branch Line from S.W, system to N.W. section. ; I <br /> i <br /> i <br /> i11. 1 A11 control valves shall have tamper switches and be tied intolFire ; <br /> ,Annunciator Panel, and indicate trouble if closed. ; i <br /> ' � . , I <br /> i 12. �IrAl1 12" Fire Hose racks shall have 12"NST hose. I <br /> � ', � <br /> Note - see attached Codes and Standards. I suggest that all concerned meet <br /> at the City Council Chambers to address eac of the above-mentioned items. <br /> � <br /> ` I <br /> �% �/�---��- I <br /> G <br /> W. T. Fenton, Fire Chief , <br /> . . <br />