Laserfiche WebLink
I <br /> � I . • � , <br /> I V <br /> � FORM �R4Q5-2014: - <br /> WALLS <br /> Adjacent Space Cavity Width Height Sheathing Framing Solar Belo w ; <br /> _ 1 E Exterior Concrete Block-Ext In�d�ster Bedro 5 8 0 8 0 64.0 ft� 0 0 0.3 0 <br /> _2 S Exterior Concrete Block-Ext In�d6ster Bedro 5 14 8 8 0 117.3 ftZ 0 0 0.3 0 '� <br /> _3 W Exterior Concrete Block-Ext In3�dhster Bedro 5 15 0 8 0 120.0 ft� 0 0 0.3 0 ' <br /> _4 W Exterior Concrete Block-Ext Insul Mtlt 5 5 8 8 0 45.3 ftZ 0 0 0.3 0 <br /> _ 5 W Extsrior Concrete Block-Ext Ins�taster Bath 5 6 4 8 0 50.7 ft' 0 0 0.3 0 I <br /> _6 W Exterior Concrete Block-Ext Insul Kitchen 5 12 8 8 0 101.3 ft' 0 0 0.3 D ; <br /> _7 E Exterior Concrete Block-Ext ins�edroom3 5 14 0 8 0 112.0 ftZ 0 0 0.3 0 ' <br /> _8 W Exterior Concrete Block-Ext Insul Laundry 5 7 8 8 0 61.3 ft' 0 0 0.3 0 j � <br /> _ 9 N Exterior Concrete Block-Ext Inst�edroom2 5 12 0 8 0 96.0 ftZ 0 0 0.3 0 <br /> _10 E Exterior Concrete Block-Ext Inst�edroom2 5 11 8 8 0 93.3 ft' 0 0 0.3 0 ; <br /> _11 N Ext�rior Concrete Black-Ext Insul Entry 5 5 0 8 0 40.0 ft� 0 0 0.3 0 <br /> _12 E Exterior Concrete Block-Ext In�deat Rm Din 5 25 _ 0 8 0 200.0 ftz 0 0 0.3 0 <br /> _13 S Exterior Concrete Block-Ext In�ndeat Rm Din 5 14 0 8 '0 112.0 ft2 0 0 0.3 0 <br /> _14 N Garage F�ame-Wood Laundry 13 5 4 8 42.7 ftZ 0.23 0.01 0 <br /> _15 N Garage Frame-Wood Bath2 13 6 4 8 50.7 ft� 0.23 0.01 0 <br /> _16 E Garage Frame-Wood Entry 13 11 8 8 93.3 ft' 0.23 0.01 0 <br /> DOORS <br /> # flmt Door Type Space Storms U-Value Width Height Area <br /> _� Ft In Ft In <br /> 1 N Insulated Entry None .35 3 6 8 20 ftZ <br /> 2 S Insulated Great Rm Din None .35 3 6 8 20 ft� <br /> 3 E Insulated Entry None .46 2 8 6 8 17.8 ft2 <br /> WINDOWS <br /> Orientation shown is the entered,Pro osed orientation. <br /> / Wa�� Overhang <br /> \/ � # Ornt iD Frame Panes NFRC U-Factor SHGC Area Depth Separation ;Int Shade Screening <br /> 1 S 2 TIM Low-E Double Yes 0.54 0.3 30.0 ft' 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5 <br /> 2 E 7 TIM Low-E Double Yes 0.54 0.3 15�0 ft2 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5 <br /> 3 N 9 TIM Low-E Double Yes 0.54 0.3 20.0 ft2 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5 <br /> 4 E 90 TIM Low-E Double Yes 0.54 0.3 15.0 ft' 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5 <br /> 5 E 12 TIM Low-E Double Yes 0.54 0.3 15.0 ft2 1 ft 0 in 0 ft 9 in Drapes/blinds Exterior 5 <br /> ' 6 E 12 TIM Low-E Double Yes 0.54 0.3 30.0 ft2 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5 <br /> 7 S 13 TINF Low-E Double Yes 0.54 0.3 12.0 ft= 8 ft 8 in 1 ft 2 in Drapes/blinds Exterior 5 <br /> ` GARAGE <br /> � # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wail Insulation <br /> 1 237.51 ft' 384 ft� 64 ft 8 ft 1 <br /> , i <br /> I <br /> � <br /> -i <br /> I <br /> � <br /> i � <br /> � i ' <br /> 11/19/2D15 1:54 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6 � I <br /> i - <br /> � <br /> ' � <br />