My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
16-17426
Zephyrhills
>
Building Department
>
Permits
>
2016
>
16-17426
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/13/2017 9:38:58 AM
Creation date
7/13/2017 9:38:07 AM
Metadata
Fields
Template:
Building Department
Company Name
WALNUT GROVE TOWNHOMES
Building Department - Doc Type
Permit
Permit #
16-17426
Building Department - Name
BUTTERFIELD MOBILE HOME SVC INC
Address
37744 PRAIRIE ROSE LP LOT 11
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I � <br /> - I <br /> I • <br /> I ' ' <br /> �1"O @Ct $L1117117af' � �ob: rt1715ass ' <br /> � wright�oftm � Y Date: 11-17-15 ' <br /> Entire House By: JND ! <br /> . Bahr's Propane Gas 8�AC Inc � I <br /> , i <br /> � 4441 Allen Rd,Zephyfiills,FL33541 Phone:813782-5013 i <br />� I <br /> ' e - • • <br /> For: Butterfield Quadplex Unit 6-1 , ' <br /> ' 4408 Court St, Zephyrhills, FL 33542 <br /> Notes: Load Calculation was obtained from an on-site inspection. <br /> � - • • • <br /> y , <br /> Weather. Lakeland Co(S), FL, US <br /> Winter Design Conditions Summer Design Conditions ' <br /> Outside db 41 °F Outside db 91 °F ' <br /> Inside db 70 °F Inside db 75 °F <br /> Design TD 29 °F Design TD 16 °F <br /> Daily range M � <br /> Relative humidity 50 % ; <br /> Moisture difference , 47 gr/Ib , <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 15350 Btuh Structure 13615 Btuh � <br /> Ducts 3379 Btuh Ducts 5710 Btuh , <br /> Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh <br />' Humidification 0 Btuh Blower 1416 Btuh � <br /> Piping 0 Btuh � <br /> Equipment load • 18729 Btuh Use manufacturer's data y � <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 20741 Btuh <br /> Method simplified Latent Cooling Equipment Load Sizing i <br /> Construction quality Average � <br /> Fireplaces 0 Structure 2200 Btuh I <br /> Ducts 1274 Btuh i <br /> Heating Cooling Central vent(0 cfm) 0 Btuh <br />� Area(ftz 1435 1435 Equipment latent load 3474 Btuh ' <br /> I olume�ft3) 11480 11480 <br /> �4ir changes/hour 0.45 0.23 Equipment total load 24216 Btuh , <br />, Equiv.AVF (cfm) 86 44 Req. total capacity at 0.75 SHR 2.3 ton , <br /> Heating Equipment Summary Cooling Equipment Summary � <br /> Make Make Tempstar or Eqv. <br /> jfrade Trade TEMPSTAR <br />'� Model Cond N4A330A(G)KC` � <br /> I AHRI ref Coil FXM4X30**A* <br /> � AHRI ref 3692289 <br /> E�ciency 100 EFF Efficiency 11.5 EER, 14 SEER � <br /> Heating input 8.0 kW Sensible cooling 20850 Btuh <br /> �leating output 27297 Btuh Latent cooling _ 6950 Btuh ' <br /> Temperature rise 96 °F Total cooling 27800 Btuh - , <br /> Actual air flow 261 cfm Actual air flow 927 cfm � <br /> � Air flow factor 0.014 cfm/Btuh Air flow factor 0.048 cfm/Btuh <br /> Static pressure 0.50 in H20 Static pressure 0.50 in H20 � <br /> Space therrviostat Load sensible heat ratio 0.86 <br /> I <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> c wri h�soft' 2015-Nov-1913:57:13 <br /> � g Right-SuiteC�J Universal 2015 15.0.21 RSU07440 Page 1 , <br /> ...Ie1R1115486-Buttertield1R1115486 Unit Si.rup Calc=MJB Building Frant faces: N <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.