Laserfiche WebLink
� � � � / f.� :� � <br /> . s . ► : 9 c7laif�o��� <br /> � SUPPLY & MANUFACTURING <br /> � � <br /> � � <br /> � <br /> � � ' i ' � • • • � <br /> • � , � � � • � � � � � • � � • <br /> � � TNi <br /> ENGI EER LOAD TABLE: 26 Ga. GulfRibT'" Panel over 15/32" Plywood <br /> Buildings having a Roof Mean Height<_ 20`-0"; Roof Slope. 2"!12" - 12"/12" Gable or Hip Roof; Wind Speeds 120- <br /> 180rr�ph, Exposure C, Risk Category II, Enclosed Building, based on Florida Building Code 2014 <br /> 120 130 140 150 160 170 180 <br /> W�� p FASTENER SUBSTRATE <br /> SPEIED (MIN.1/4" �MIN.15/32") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER <br /> Penetration) SPACING SPACING SPACING SPACING SPACING SPA�ING SPACING <br /> ZONE 1 #9-15x1.5" PIyWOOd 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 <br /> i <br /> ZO E 2 #9-15x1.5" Plywood 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 12",NPE 2 <br /> ZONE 3 #9-75x1.5" PfywOOd 24",TYPE 1 24",TYPE 1 24",TYPE 1 12",TYPE 2 12",TYPE 2 12",TYPE 2 12",TYPE 2 <br /> 1.)PANEL DESCRIPTION:GULFRIBT"', MIN.26 GA., GRADE 80, 36"COVERAGE, 3/4"TALL. <br /> 2.)PANEL FASTENER:#9-15X1 5" HWH WITH SEALING WASHER OR APPROVED EQUAL <br /> 3.)MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE:69.25 PSF C�24" 0 C FASTENER SPACING TYPE I FASTENER PATTERN, 159.25 <br /> PSF @�I 12" 0 C FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING <br /> 4.)P�YjWOOD DECKING: MIN 15/3z"THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2014 <br /> 5.)ROOF SLOPE:ON ROOF SLOPES LESS THAN 3 12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS <br /> 6.) L �AD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10(KD=0 85)MULTIPLIED BY 0 6 PER FLORIDA BUILDING <br /> COD�2014 ' <br /> HIP ROOF a Note:Dimension(a)is defined as 10%of the minimum width of the building or <br /> ��,ZONE2 ZONE 3—�I i 40°/a of the mean height of the roof,whichever is smaller,however,(a)cannot be <br /> - ,;� _______ 'a less than either 4%of the minimum width of the building or 3 feet. <br /> � •` ��y, ��� TYPE 1 FASTENEA PAT7EAN <br /> � � I <br /> i ��\ �'� �� �RI�GE �r /� i 9.�,___9�� 9��_#__9w <br /> ; �' �---�-----� \ ! � � � � AtPanelLap <br /> � --------- <br /> � �� /� ~�� �� I // <br /> � i ZONE 7 � � L Cont.Taoe Seal tor us2 on Slopes less tha�3:12 <br /> i i � �� {t)#9-15x1-1I2'wiSealerWasher�'"�n 24'O.C.61ax. <br /> / <br /> �-----------------\� <br /> � <br /> `�—EAVE <br /> TYPE 2 FASTENER PATfERN <br /> �Ez GABLEROOF I� i-6.5"—{-2.5"-t-6.5"—{-2.5'-{-6.5"—{-2.5"-{-6.5°—{-2.5„ <br /> --� <br /> :�—��-----------------� —�a I I I I I � I , <br /> � � � � ! 1 <br /> � � \� rRIDGE � L Carrt.Taao fieal fcr usa on Siepes lass than 3�12J <br /> i �� i � {t)�&t5 x t-t/2'wiSealer Wuher p t2'O.C.AWx. <br /> -� -� - - -; ,a <br /> —Ta <br /> --------- -------i � <br /> , <br /> �� ZONE 1 ; <br /> I��, I <br /> ---�`,------------------- - <br /> �20NE 3 � EAVE <br /> FL 11651.22 R2•JUNE 15,2015 <br /> « <br /> s s � � e d � r s o a <br /> 1 <br /> � , ■ <br /> 0 1 � i � � � �i � � �� • <br />