1
<br /> �
<br /> INST�LLATION SPECIFICATIONS:
<br /> Titanium° UDL-25 PLUS, Titanium� UDL-30, Titanium° UDL-50, UDL TTMC-300, UDL TT, UDL TF,
<br /> RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic �i
<br /> Undei�layments I
<br /> 1. Titanium�UDL-25 PLUS,Titanium�UDL-30, Titanium�UDL-50, UDL TTMC-300,UDL TT, UDL TF,
<br /> RhinoRoof U10,RhinoRoof U15,RhinoRoof U20,Titanium UDL25, and RhinoRoof RSA Synthetic
<br /> Underlayments shall be installed in strict compliance with applicable Building Code.
<br /> 2. Titanium�UDL-25 PLUS,Titanium�UDL-30, Titanium�UDL-50,UDL TTMC-300,UDL TT, UDL TF,
<br /> RhinoRoof U10,RhinoRoof U15,RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic
<br /> Underlayments shall be installed with a minimum 4-inch head lap in a shingle layer fashion.
<br /> 3. Titanium�UDL-25 PLUS,Titanium�UDL-30, Titanium�UDL-50, UDL TTMC-300,UDL TT,UDL TF,
<br /> RhinoRoof U10,RhinoRoof U15,RhinoRoof U20, and Titanium UDL25 Synthetic Underlayments shall be
<br /> fastened with Miami-Dade approved corrosion resistant tin-caps and 12 gauge 1 '/a"annular ring-shank nails,
<br /> spaced 6"o.c. at all laps and three staggered rows fastened 12" o.c. in the field of the roll.
<br /> 4 Titanium�UDL-25 PLUS,Titanium�UDL-30, Titanium�UDL-50, UDL TTMC-300,UDL TT,UDL TF,
<br /> RhinoRoof U10,RhinoRoof U15,RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic
<br /> Underlayments may be used with Asphaltic shingles, Wood shakes and shingles,Non-structural metal roofing,
<br /> and quarry slate.Titanium�UDL-30,Titanium�UDL-50,UDLTTMC-300,UDL TT, UDL TF,RhinoRoof
<br /> U10,RhinoRoof U15,RhinoRoof U20,Titanium UDL25 and RhinoRoof RSA Synthetic Underlayments shall
<br /> not be used as roof tile underlayments.
<br /> 5 For Roof Tile applications; Titanium`�UDL-25 PLUS may be used as an anchor sheet in roof tile applications
<br /> when used in combination with a top membrane layer, consisting of a Miami-Dade approved TAS 103 self-
<br /> adhering underlayment. (See current NOA listing of approved TAS 103 self-adhering underlayment for
<br /> installation guidelines and limitations of use).
<br /> 6 For fire classification of specific roof assemblies using Titanium� UDL-25 PLUS, Titanium� UDL-30,
<br /> Titanium�UDL-50, UDL TTMC-300, UDL TT,UDL TF, RhinoRoof U10, RhinoRoof U15, RhinoRoof U20,
<br /> I Titanium UDL25, and RhinoRoof RSA Synthetic Underlayments_refer to a current Approved Roofing
<br /> Materials Directory for fire ratings of this product.
<br /> BUI DING PERMIT REQUIREMENTS:
<br /> Application for building permit shall be accompanied by copies of the following:
<br /> 1. This Notice of Acceptance.
<br /> 2. Any other documents required by the Building Official or applicable building code in order to properly
<br /> evaluate the installation of this material.
<br /> NOA No.: 14-0603.18
<br /> r�naM�•�an�couNnr Expiration Date: 08/08/18
<br /> Approval Date: 06/11/15
<br /> Page 4 of 5